Ravenheat CSI 85 B User Manual Download Page 2

2. 

OPERATING DOMESTIC HOT WATER

2.0 

Select         only switch position (1).

2.1 

Open hot water tap. 

 

After about 3 seconds burner will always operate.

2.2 

Temperature of domestic hot water can be varied 

by adjusting the water flow rate at the tap. 

 

Domestic  thermostat  (5)  will  control  maximum 

temperature leaving the appliance. 

 

The knob can be set between minimum and maxi-

mum approximately 35 °C to 65 °C (95F to 1 49F).

 

For maximum temperature of domestic hot water 

leave in maximum position.

3. 

OPERATING HEATING & HOT WATER

 

 

TO SET AND ADJUST BUILT-IN TIMER MODEL 

SEE OPPOSITE PAGE 3.

3.0 

Select                  switch (2) position.

3.1 

Switch on time clock, adjust room stat and/or  

 

thermostatic radiator valves to high settings.

3.2 

Burner  will  operate.  Temperature  output  of  

central  heating  can  be  adjusted  by  central  

heating thermostat (4). 

 

The  knob  can  be  set  between  minimum  and 

maximum approximately 40 °C to 85 °C (1 40F 

to 1 85F). 

 

While  the  appliance  is  being  used  to  provide 

domestic  hot  water,  the  central  heating  will  not 

operate. 

 

When  hot  water  is  no  longer  required  the  

appliance will automatically revert to central hea-

ting and should not noticeably affect the level of 

central heating. 

 

Adjust external controls to required settings.

NOTE:  An  anti-cycling  device  is  fitted  to  the  

heating function. 

When  the  boiler  reaches  its  set  maximum  

temperature  it  will  not  operate  on  heating  for 

about 4 minutes but the domestic hot water func-

tion will always operate on demand.

3.3 

TO SHUT DOWN THE APPLIANCE

3.3.1   For short periods, switch to             only and turn 

off all hot taps. For long periods switch of the on/

off switch (1). 

 

If  the  appliance  is  to  be  shut  down  for  long 

periods  when  there  is  a  risk  of  freezing,  then  

appliance should be drained. 

 

Similar refilling must be done by a competent per-

son following approved procedures.

4. 

CLEANING OF APPLIANCE OUTER CASING

4.1 

Use a clean damp cloth. 

 

Do not use any abrasive cleaners end with a dry 

cloth lightly polish to protect painted surfaces.

Control  panel  and  fixtures  can  be  wiped  with 

damp  cloth  and  dried.  Spray  polishes  must  not 

be used on control panel surfaces or switches. 

Care  must  be  taken  in  preventing  any  liquids  

entering the appliance.

4.2 

CARE OF YOUR APPLIANCE AND SYSTEM

42.1 

Annual servicing of your appliance is required to 

maintain  safety  and  efficiency  of  its  operation. 

Therefore it is recommended that the appliance 

is serviced at least once a year and that the who-

le of the heating system be checked at the same 

time by a qualified installer. 

 

If it is known or suspected that a fault exists on 

the  boiler  then  it  MUST  NOT  be  used  until  the 

fault  has  been  corrected  by  a  COMPETENT 

PERSON.

 

It is essential that the instructions in this booklet 

are strictly followed for safe and economic opera-

tion of the boiler.

SERVICING  SHOULD  BE  CARRIED  OUT  BY  A  

QUALIFIED INSTALLER.

For Evaluation Only.

Copyright (c) by Foxit Software Company, 2004

Edited by Foxit PDF Editor