9
TM-1 Set Up & Configuration
Calibrate To Level Ground.
On level ground the current reading should display a zero tilt angle. If the display
shows a non-zero tilt angle on known level ground, touch the
Calibrate To Level Ground
button to recalibrate
the TM-1 to a level condition.
Using the Envizio Pro or Envizio Pro II
If the TM-1 Tilt Sensor is connected directly to the DGPS connector on the main interface cable, the field
computer may be used to configure the TM-1. Touch the Tilt icon to access the Tilt Configuration screen.
The following features and settings may be set from this screen:
Note:
The antenna height setting is not displayed on the Tilt Configuration screen. Refer to the field
computer Installation & Operation Manual for information on this setting.
Filter Speed.
Use the sliding bar to select the filter speeds best suited for the field conditions. The filter speed
may be set to off, slow, medium, and fast. Touch the
Information
icon to view an explanation for the different
settings.
Note:
Rougher terrain will require slower filter speeds. To provide the best possible tilt compensation,
select the fastest filter speed that provides a stable guidance path.
Polarity.
This feature is currently not in use. Set this option to high.
Current Tilt.
This is a display only. This displays the current tilt angle observed by the TM-1 Tilt Module.
Note:
The maximum tilt angle which the TM-1 may register is ±45° from a level surface.
Calibrate.
On level ground the current reading should display a zero tilt angle. If the display shows a non-zero
tilt angle on known level ground, touch the
Calibrate
button to recalibrate the TM-1 to a level condition.