![Raven Sidekick Pro ISO Installation & Operation Manual Download Page 26](http://html.mh-extra.com/html/raven/sidekick-pro-iso/sidekick-pro-iso_installation-and-operation-manual_789032026.webp)
C
HAPTER
3
22
Sidekick Pro™ ISO Installation & Operation Manual
FIGURE 10. Sidekick Pro™ ISO Pump Mounting Bracket Bolt Pattern
SIDEKICK PRO™ ISO INJECTION SYSTEM PLUMBING
PLUMB THE SIDEKICK PRO™ ISO PUMP
PUMP INLET
Use 3/4” chemically resistant hose between the chemical tank and injection pump inlet. Do not use hose or tubing
that may collapse when a vacuum is applied during pump operation.
The product line should be as straight as possible. Avoid low spots in plumbing to ease pump priming and avoid
chemical waist.
STRAINER
A strainer with a #20 mesh screen must be installed on the inlet side of the injection pump.
PUMP OUTLET
Connect the pump outlet to the injection check valve at the point of injection. Use the following hose sizes
depending upon the capacity of the injection pump used with the system.
Pump Capacity
Hose Size
1-40 oz./min.
3/8”