![Raven Sidekick Pro ISO Installation & Operation Manual Download Page 20](http://html.mh-extra.com/html/raven/sidekick-pro-iso/sidekick-pro-iso_installation-and-operation-manual_789032020.webp)
C
HAPTER
3
16
Sidekick Pro™ ISO Installation & Operation Manual
TABLE 1. Check Valve Sizing and Selection Chart
Raven Part
No.
Inlet
Outlet
Flow
Coefficient
a
a. The flow coefficient (C
v
) is the volume per minute (water) at which the pressure
drop equals 1 PSI [6.9 kPa].
Recirculation and
Priming Check
Valve
b
b. “046” Identifier. Rated for 12 PSI [82.7 kPa] and has 0.046” bleed hole. Verify the
check valve is installed with the flow arrow pointing in the direction of flow through
the valve.
333-0011-100
1/2” (F)
1/2” (M)
N/A
Injection Point
Check Valve
c
c. “102” Identifier. Rated for 12 PSI [82.7 kPa] Verify the check valve is installed with the
flow arrow pointing in the direction of flow through the valve.
333-0011-102
1/2” (F)
1/2” (M)
N/A
Carrier Check Valve
333-0011-090
1”
1”
14
333-0011-091
1-1/4”
1-1/4”
22
333-0011-104
m220 Banjo
Flange
m220 Banjo
Flange
70
333-0011-105
m330 Banjo
Flange
m300 Banjo
Flange
110
Summary of Contents for Sidekick Pro ISO
Page 8: ...CHAPTER 1 4 Sidekick Pro ISO Installation Operation Manual ...
Page 16: ...CHAPTER 2 12 Sidekick Pro ISO Installation Operation Manual ...
Page 46: ...CHAPTER 4 42 Sidekick Pro ISO Installation Operation Manual ...
Page 70: ...CHAPTER 7 66 Sidekick Pro ISO Installation Operation Manual ...
Page 80: ...Index 76 Sidekick Pro ISO Installation Operation Manual ...