2.2. Checking the hydraulic manifold
The hydraulic implement manifold is suited for
use in both Load-Sense (L.S.) and Open Centre
(O.C.) hydraulic systems. Depending on the
type of installation a different type of selector
plug must be installed in the manifold (Table 2,
Figure 7).
Check the type of the selector plug (Figure 8)
before mounting the manifold.
If the manifold is connected to the auxiliary
hydraulic connectors at the rear of the tractor,
the manifold must be configured in Open
Centre mode. The LS connector must be
capped.
When Open Centre is chosen, other
selector plugs need to be used in the
manifold when Load Sense is used!
The implement manifold is equipped with two
double
controlled non-return valves by default
(Flucom CAP20/M)
. If the hydraulic system of
the plough is already equipped with such plugs,
the ones in the manifold need to be replaced
with blind plugs (
The double
controlled non-return valves
need to be replaced by blind plugs when
the hydraulic system of the plough is
already equipped with similar valves.
Type of hydraulics Selector plug
Load Sense
SBG10810
Blind plug without imprint
Open Centre
SBG10820
ELP30/D2
Table 2 Selector plug manifold
Figure 8 Selector plug
Figure 7 Selector plug. Left: L.S. Right O.C.
Figure 9 Above: blind plug Under: double controlled
non return valves (Flucom CAP20/M)