SBGuidance Onland Plough I Version 1.3 I CAN
SBG-Onland-Plough-IM-EN-V1.3 I
Pag 15/
39
3. Depending on the range choose a hole
in the sensor arm to mount the ball joint.
To determine see Table 1and Figure 6.
By choosing the optimal hole an as wide
as possible voltage range in the sensor
is obtained. Now the position of the ball
joint on the regulation beam can be
determined. Mark that place, drill a hole
and tap thread.
Range sensor (cm)
Hole to use on sensor
arm
< 3,5
1
3,5
– 5,5
2
5,5
– 7,5
3
7,5
– 9,5
4
9,5
– 12,5
5
4. After installation check if the sensor can
move freely and if the movement is
within the linear range (1,0 to 4,0 V) of
the sensor.
The linear range of the angle sensor lies
between 1,0 and 4,0V.
5. Connect the sensor cable to the sensor
and guide it towards the front of the
plough. Mount the cable in a protective
tube and make sure the cable isn’t
pinched or squeezed while turning
and/or modifying plough width.
Table 1 Holes angle sensor arm
Figure 6 Holes angle sensor arm