![Raven OmniSeed Viper Pro Calibration & Operation Manual Download Page 22](http://html.mh-extra.com/html/raven/omniseed-viper-pro/omniseed-viper-pro_calibration-and-operation-manual_788947022.webp)
Chapter 2
10
OmniSeed™ Viper Pro™ Installation & Operation Manual
Viper Pro Care and Use
Refer to the following guidelines for proper care and use of the Viper Pro field computer.
•
Do not apply any type of liquid or glass cleaner directly to the surface of the touch screen. Harsh chemicals
may damage the touch screen. Clean the touch screen and field computer exterior as needed with a soft
cloth dampened with glass cleaner. Apply the cleaner to the cloth and then wipe the screen gently.
•
Do not use any type of pointed or sharp instrument on the touch screen. Only a fingertip or approved stylus
should be used when interfacing with the field computer.
•
Do not expose the Viper Pro field computer to precipitation, condensation, or other liquids. Store the
computer in a dry environment when not in use.
•
Mount the field computer securely and route cables to avoid tripping hazards and to keep the wires from
pinching or breaking.
•
When temperatures are expected to be 32° F [-0° C] or lower, remove the field computer from the vehicle
and store it in a climate controlled environment.
•
Damage to the field computer may occur if the USB ports are used to charge mobile devices such as
cellular phones, tablets, or mp3 devices. The USB ports should only be used for performing file transfer and
maintenance.
Technical Specifications
CAUTION
U.S.
Metric
Dimensions
Height
12.04 in.
[30.58 cm]
Width
8.95 in.
[22.73 cm]
Depth
2.98 in.
[7.57 cm]
Diagonal
10.4 in.
[26.42 cm]
Weight
4.7 lbs.
2.13 kg
Environmental
Operating
Temperature
32° F to 158° F
0° C to 70° C
Storage
Temperature
-4° F to 185° F
-20° C to 85° C
Power
Operating
Voltage
9 VDC to 28 VDC
Reverse Polarity Protected
Ports
USB
3 (1 on front, 2 on back)
Ethernet
1 (Back)
Amp
2 (Back)
Mounting
Clamp
a
(Provided)
a.Designed to secure the field computer to a 1” dia. [2.54 cm] monitor
bar or post.
1.020 in. dia.
2.59 cm dia.
Thumb Screws
(Provided)
1/4”-20 x 1” Long
Summary of Contents for OmniSeed Viper Pro
Page 1: ...Viper Pro Software Version 3 10 OmniSeed Calibration Operation Manual ...
Page 10: ...Table of Contents viii OmniSeed Viper Pro Calibration Operation Manual ...
Page 98: ...Chapter 4 86 OmniSeed Viper Pro Installation Operation Manual ...
Page 150: ...Chapter 6 138 OmniSeed Viper Pro Installation Operation Manual ...
Page 222: ...Chapter 10 210 OmniSeed Viper Pro Installation Operation Manual ...
Page 240: ...Chapter 11 228 OmniSeed Viper Pro Installation Operation Manual ...
Page 251: ...Manual No 016 3001 015 Rev C 239 FIGURE 2 OmniSeed System Diagram 3 Bin D N 054 3001 026 ...
Page 256: ...Appendix A 244 OmniSeed Viper Pro Installation Operation Manual ...
Page 284: ...Appendix D 272 OmniSeed Viper Pro Installation Operation Manual ...
Page 292: ...Appendix G 280 OmniSeed Viper Pro Installation Operation Manual ...
Page 300: ...Appendix H 288 OmniSeed Viper Pro Installation Operation Manual ...
Page 304: ...Index 292 OmniSeed Viper Pro Calibration Operation Manual ...
Page 307: ......