![Raven OmniSeed Viper Pro Calibration & Operation Manual Download Page 101](http://html.mh-extra.com/html/raven/omniseed-viper-pro/omniseed-viper-pro_calibration-and-operation-manual_788947101.webp)
5
Manual No. 016-3001-015 Rev. C
89
Using the OmniSeed Viper Pro System
CANbus Rate Control.
The Viper Pro field computer is capable of controlling product application directly via a
Raven CANbus using Raven product nodes. Each node provides a single control channel for controlling the
application of a single product. So, if the Viper Pro is connected to a CANbus with a single product node, the
Viper Pro will monitor or control for one product during an active job. Up to five product nodes may be
connected to the Viper Pro to control any combination of liquid, granular, injection or spinner channels as
necessary. In this configuration, the Viper Pro is directly controlling the product control valves and other
hardware.
Note:
A multi-product variable rate key must be purchased and authorized in order to provide multi-
product VRA within a job. Contact a local Raven dealer to acquire the activation key and refer to
the Registering the Viper Pro section on page 23 for assistance entering the activation code on the
Viper Pro field computer.
Swath Guidance
When the swath guidance feature is enabled, the Viper Pro may provide on-screen guidance paths based
upon the programmed machine or equipment width. The swath guidance path displayed on the Viper Pro
provides a quick reference to the vehicle location in relation to previous coverage and may be used with an
automated steering system such as the Raven SmarTrax systems to automatically steer the vehicle using the
displayed guidance path.
The Viper Pro is capable of providing guidance for several crop or field patterns to suit field conditions and
application types.
Liquid Section Control
The liquid section control feature allows the Viper Pro to automatically turn liquid product sections on or off by
referencing the coverage map. While Viper Pro creates the coverage map, the system references previously
applied areas and the vehicle location to automatically turn liquid sections off in turn as the implement crosses
over previously applied areas. As sections re-enter un-applied area, the Viper Pro turns the liquid section back
on.
, for more information on using the OmniSeed section control
feature with the Viper Pro field computer.
Summary of Contents for OmniSeed Viper Pro
Page 1: ...Viper Pro Software Version 3 10 OmniSeed Calibration Operation Manual ...
Page 10: ...Table of Contents viii OmniSeed Viper Pro Calibration Operation Manual ...
Page 98: ...Chapter 4 86 OmniSeed Viper Pro Installation Operation Manual ...
Page 150: ...Chapter 6 138 OmniSeed Viper Pro Installation Operation Manual ...
Page 222: ...Chapter 10 210 OmniSeed Viper Pro Installation Operation Manual ...
Page 240: ...Chapter 11 228 OmniSeed Viper Pro Installation Operation Manual ...
Page 251: ...Manual No 016 3001 015 Rev C 239 FIGURE 2 OmniSeed System Diagram 3 Bin D N 054 3001 026 ...
Page 256: ...Appendix A 244 OmniSeed Viper Pro Installation Operation Manual ...
Page 284: ...Appendix D 272 OmniSeed Viper Pro Installation Operation Manual ...
Page 292: ...Appendix G 280 OmniSeed Viper Pro Installation Operation Manual ...
Page 300: ...Appendix H 288 OmniSeed Viper Pro Installation Operation Manual ...
Page 304: ...Index 292 OmniSeed Viper Pro Calibration Operation Manual ...
Page 307: ......