REM LED CODES
SYSTEM SUMMARY
The
System Summary
window displays the machine configuration information.
FIGURE 25. System Summary
TABLE 3. REM Node LED Status
LED
Color
Hz
Status Name
Description
Power
Green
Solid
ECU Powered
Active when ECU has high current
power.
A
Off
Solid
Microprocessor
Off
Active when the microprocessor is
not powered.
A
Red
1
ISOBUS Offline
Active if the ISOBUS is offline.
A
White
1
ISOBUS Online
Active if the ISOBUS is online.
A
Green
1
Systems Normal
Active when linked with VT and
system is normal.
B
Red
1
ECU Power Loss
System has lost Logic power, but
not high current power.
B
Off
Solid
ECU Has Power
System has logic power and high
current power.
C
Red
Solid
FPGA Not
Running
PCB subsystem not running
(FPGA).
C
Green
Solid
LED C Functional
- No Error
LED C is functional and there are
no other LED C states to report.