Use and maintenance manual RC-RV 120 Touch Steel
Pag.32
Rev.1 16/06/2021
EN
Testing and commissioning
Stove start-up must be preceded by testing, which includes an operational check of the following elements:
•
connection to the smoke evacuation system;
•
electrical connections;
•
operation of any connected external probes;
•
checking that all materials used to build the smoke duct, chimney and chimney pot are regulation and suitable for use.
The testing is positive only when all operational phases have been completed without any anomaly being detected.
Electric scheme RC 120 Touch Steel
LEGENDA:
Sicurezze
T4 - Sicurezza pellet
T5 - Pressostato
Motori
M1 - Motoriduttore coclea
M2 - Pulitore automatico
(solo stufe con pulitore automatico)
M3 - Estrattore fumi
M4 - Scambiatore (frontale per stufe
con doppia canalizzazione)
M5 - Scambiatore DX (stufe con
doppia canalizzazione)
M6 - Scambiatore SX (stufe con
canalizzazione doppia)
T1 - Contatto Sportello fuoco (se presente)
T2 - Contatto cassetto cenere (se presente)
T3 - Contatto serbatoio pellet (se presente)
Resistenza
R1 - Resistenza
Sonde
S2 - Sonda fiamma (K) (se presente)
S3 - Termostato esterno
S4 - Sonda ambiente (opt)
Generico
G1 - Debimetro (solo stufe con tecnologia RDS)
G2 - Encoder lettura giri estrattore
G3 - Palmare “RADIO” Touch
G4 - Conta colpi pulitore automatico
(solo stufe con pulitore automatico)
G5 - Contatto gestione domotica
G6 - Contatto accensione GAS -
Segnalazione allarme uscita
domotica (TRF 39)
RETE
ALIMEN
TAZIONE 220 V
S4
G4
G5
G2
N
COM
NC
NO
G6
G2
NC
G6
NO
G6
C
G6
G5 G5
10 9 8 7 6 5 4 3 2 1
Connessione OPZIONALE per
gestione domotica
Neutro
M4
M5
M6
Fase
Connessione SON
D
A o
T.EXT
Rear LEFT
Connessione SON
D
A o
T.EXT
Rear
RIGHT
T1
T5
T3
T2
T4
M1
M2
M3
S2
R1
S3
G1
G3
S1
S1 - Sonda fumi (se presente)
LEGEND
Safeties
T1 - Fire door contact
T2 - Ash drawer contact
(if applicable)
T3 - Pellet hopper contact
T4 - Pellet thermal safety
T5 - Pressure switch
Motors
M1 - Auger gear motor
M2 - Automatic cleaner
M3 - Flue gas fan
M4 - Frontal Heat exchanger
M5 - Right Heat exchanger
M6 - Left Heat exchanger
Resistance
R1 - Igniter
Probes
S1 - Flue gas probe (J)
S2 - Flame probe (K)
S3 - External thermostat
S4 - Room probe (opt)
Generic
G1 - Air-flow meter
G2 - Encoder for reading extractor rpm
G3 - RADIO Touch handheld remote control
G4 - Automatic cleaner stroke counter
G5 - Home automation management contact
G6 - GAS ignition contact -
Home automation output alarm signalling (TRF 39)