Spreading operation with the QUANTRON-A control unit
5
92
5.4
Spreading in the AUTO km/h operating mode
In AUTO km/h operating mode, the control unit automatically controls the actua-
tor depending on the speed signal.
1.
Configure the fertiliser settings:
Application rate (kg/ha)
Working width (m)
2.
Insert fertiliser.
3.
Carry out a calibration to determine the flow factor
or
Obtain the flow factor from the fertiliser chart.
4.
Enter the flow factor manually.
5.
Press the
Start/Stop
key.
The spreading starts.
NOTICE
In order to achieve an optimum spreading result in the AUTO km/h operating
mode, a calibration is to be carried out before starting the spreading work.