1 Read operator’s manual
DANGER!
Risk of death or injury from using
the machine incorrectly.
▶
Read operator’s manual
before
using
the
machine.
2 Connecting the machine
control unit
3 Pre-setting the mounting
height
V [mm]
max.
H [mm]
max.
Normal
fertilizatio
n
850
850
Late
fertilizatio
n
770
830
4 Setting the spreading
vane
Spreading disc M1
Position
• A to E: Length settings
• 1 to 6: Angle settings
Spreading disc M2
• Only the angle can be adjusted
with the W spreading vane; the
length is fixed.
5 Connecting the
electronic slide
actuators
NOTICE!
Property damages caused by
incorrect positioning of the
metering slide
If the stop levers are positioned
incorrectly, the operation of the
actuators via the QUANTRON-A
operating
unit
may
cause
damage to the metering slides.
▶
Always clamp the stop
levers at the maximum
scale position.
The stop must be secured in a
position outside of the scale using
a hexagon nut with cover [1].
6 Checking the machine
settings
7 Entering fertilizer
settings
Quick reference guide
MDS.2 Q/W
Read operator’s manual before using the machine
5903462-
a