APPENDIX
51
Checking
Combination Switch
When the combination switch in each position. Checking
the ignition circuit, fuel switch, choke switch status
Close switch is "OFF", the ignition circuit is turned
off, namely two micro switch output terminal is turned on,
the ignition grounding; oil switch is turned off, the engine
would not run.
When the combination switch is "ON", the ignition
circuit is in working condition, that both the output
terminals micro switch off; oil switch is turned on; the
choke is fully open state, the engine can be run properly.
When the combination switch in the "CHOKE", the ignition circuit is in working condition, that two
output terminals micro switch off; oil switch is turned on; the choke in the closed state.
When the switch is in the respective positions. The continuity between the switch terminals to be checked.
WIRE
Removing the wire harness from the panel, rectifier
and the inverter. Check wire insulation for any obvious
damage. If it is damaged, replace the harness.
Using an ohmmeter check continuity of each wire,
confirm that each wire is turned on. If infinite resistance,
replace the harness.