background image

- 1 -

Precautions

Warning

Working temperature range

※ 

Operating Temperature Range

Indoor side DB/WB(°C)

Maximum cooling

32/23

43/-

Maximum heating

27/-

24/18

Outdoor side DB/WB(°C)

The operating temperature range (outdoor temperature) for cooling only unit is 

18°C~ 43°C.

electric shock.

Please contact dealer when you need to repair air conditioner.

injury or damage.

sensory or mental capabilities, or lack of experience and knowledge, unless they

have been given supervision or instruction.

● Do disconnect power supply when clea

ning air conditioner. Otherwise, it may cause

● Do not repair air conditioner by yourself

. It may cause electric shock or damage.

● Maintenance must be performed by qualified professionals.Othe

rwise, it may cause

● The appliance is not to be used by persons (including childre

n) with reduced physical,

● Children being supervised not to play w

ith the appliance.

Please install the devices for short-circuit protection and electrical leakage protection

According to the local safety regulations, u

se qualified power supply circuit and circuit 

when installing the air conditioner.

break.

Children shall not play with the appliance.

Cleaning and user maintenance shall not be made by children without supervision.
The air conditioner should be installed in accordance with national wiring regulation.

Air Conditioner should be properly grounded. Incorrect grounding may cause electric 

shock.

hazard.

broken.

injury or damage.

personal injury.

● Do not connect air conditioner to multi-purpose socket.Otherw

● This appliance can be used by children aged from 8 years and 

above and persons  

ise, it may cause fire 

● Do install the air switch. If not, it may cause malfunction.

● Do not spill water on the remote controller’otherwise the rem

ote controller may be

● Do not spray water on air conditioner. It may cause electric 

shock or malfunction.

● Do not extend fingers or objects into air inlet or air outlet

. It may cause personal

● Do not step on air conditioner, or put heavy objects. It may 

cause damage or

 

● Do not block air outlet or air inlet. It may cause malfunction

.

with reduced physical, sensory or mental capabilities or lack of experience and   

knowledge if they have been given supervision or instruction concerning use of the   

appliance in a safe way and understand the hazards involved.  

Summary of Contents for RC-X7H

Page 1: ...Thank you for purchasing Rasonic window type air conditioner Please read the user manual carefully before installation and well keep user manual for your later reference Model RC X7H RC X9H RC X12H RC...

Page 2: ...Care and maintenance 3 3 4 7 2 Precautions 1 After service 19 This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of exper...

Page 3: ...t if not avoided could result in death or serious injury Indicates a hazardous situation that if not avoided may result in minor or moderate injury Indicates important but not hazard related informati...

Page 4: ...circuit when installing the air conditioner break Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision The air conditioner should...

Page 5: ...brary and laboratory and so on Room temp Spring Summer Autumn Wind direction Winter Cooling in summer In hot summer Air conditioner can cool down theroom air by transferring heat out Without reducing...

Page 6: ...water af ter running for so much time But this is normal Water pipe The electric components will be damaged when the voltage is too high If the voltage is too low the compressor will vibrate violently...

Page 7: ...us gas or other special areas please contact the seller before use Avoid a place where is possible for inflammable gas to leak out Avoid other heat sources or direct sun light Avoid a place where is e...

Page 8: ...he enlargement of noise or vibration 3 Fill up sews in the cabinet with sponge or foam Installation assistance Use iron support The installation hole should be strong enough to support the air conditi...

Page 9: ...the drain pan to the corner of the cabinet with 2 screws 4 Connect the drain hose to the outlet on the drain pan bottom 5 Slide the chassis into its original place in the cabinet Drain water for one s...

Page 10: ...ble socket can t be used because poor contact of it can cause over heat or fire If the supply cord is damaged it must be replaced by the manufacturer or your dealer In fixed circuit there must be elec...

Page 11: ...itioning the vane to discharge the air upwards downwards or straight out Air direction adjustment 8 Part identification Front grille Air inlet louver Cabinet Air filter behind the front intake grille...

Page 12: ...ON OFF button MODE button button FAN button SWING button SLEEP button TIMER button Timer on Timer off Sending signal swing operation sleep operation lock set speed Set time Set temperature heat operat...

Page 13: ...set temperature Press FAN button to adjust fan speed When selecting dry mode air conditioner will operate at low fan speed under dry mode In dry mode fan speed can t be adjusted When selecting fan mod...

Page 14: ...ton to set Timer Off T OFF and H icon will be blinking Within 5s press or button to adjust the time for Timer Off Pressing or button once will increase or decrease the time by 0 5h Hold or button for...

Page 15: ...ntroller won t send signal Child lock function Temperature display switchover function Under OFF status press button and MODE button simultaneously can switch between C and F Operation guide 1 After p...

Page 16: ...Make sure positions for pole and pole are correct 3 Reinstall batteries box cover The distance between signal sender and receiving window should be no more than 8m and there should be no obstacles bet...

Page 17: ...1 hour increments and Press the keypad to decrease the selected time in 1 hour decrements The time seting range is from 0 24 hours 4 TEMP TIMER BUTTON Press the keypad to increase the set operating t...

Page 18: ...the room Air can t be discharged to the di rection of air in Make sure that the doors and win dows are tightly closed Avoid open ing doors and windows frequently to keep air conditioning in the room...

Page 19: ...Do not pull out the power cord Damage to the cord may result in serious electric shocks s plastic parts will melt if exposed to excessive heat Avoid exposing the body directly to a continuous unidire...

Page 20: ...let and outlet of outdoor unit are blocked or not Let the filter dry thoroughly before reinstalling it If necessary please ask the professional personnel to clean it 2 Vacuum the filter on the dusty s...

Page 21: ...be mixed with the smell of furniture and smoke For a noise that sounds like water flowing This is the sound of freon flowing inside the air con ditioner unit For a noise that sounds like a shower Thi...

Page 22: ...owing events occur The circuit breaker frequently trips or the fuse blows regularly If water or foreign objects have accidentally entered the air conditioner If there is abnormal sound during operatio...

Page 23: ......

Page 24: ...KWAI CHUNG NEW TERRITORIES HONG KONG TEL 852 2406 5666 FAX 852 2408 0316 WEBSITE www shesc com CONSUMABLES ACCESSORIES SALES HOTLINE TEL 852 2406 5666 CUSTOMER SERVICE CENTRES 2 1 1ST FLOOR SHUN HING...

Reviews: