Third Step: Controller Box Setting

In order to link the controller to Art-Net for more flexible control, please define your 
parameters by choosing settings from the following three submenus:

- IP Address

an be arbitrarily changed, the numerical requirements and computers, and other Art-Net
device in the same gateway, IP segment is consistent, and IP can't conflict. Numerical range
for the standard IP address range, namely 0 ~ 255 Changes

- SubNet Mask

Subnet mask can be 255.255.255.0 (also can be set into 255.0.0.0 or 255.255.0.0).Gateway 
and must be consistent and DNS, the first three Numbers also must agree and IP

- Net SubNet Universal

Can be used to change for the domain and the range is 000.00.00 to 000.16.16. According to
the way we put device(controller), in order to make changes. This value can be changed, in
behind the computer convenient irregular put after some adjustments. After confirmation,
click the MENU button to return to, universe setup complete.

Advice: start from 000.00.00

Kling-Net Mode

At power-up, the Blade is detected and configured automatically by Kling-Net. Refer to your 
Kling-Net manual for more information.

Summary of Contents for Blade

Page 1: ...QUICK USER MANUAL RASHA PROFESSIONAL A S Rasha Professional A S 1800 Rustin Ave Riverside CA 92507 951 654 3585 Rashaprofessional com info rashaprofessional com 1 Blade Terra...

Page 2: ...asha Professional A S 1800 Rustin Ave Riverside CA 92507 951 654 3585 Rashaprofessional com info rashaprofessional com How to turn the controller line from 3 pins into 5 pins plug and sockets Terminat...

Page 3: ...ling service Respect the local environmental rules If in doubt contact your local waste disposal authorities Thank you for choosing this product Please read the manual thoroughly before bringing this...

Page 4: ...t accept responsibility for any ensuing defects or problems Due to constant product improvements the actual product appearance might differ from the shown images Product image Keep this manual for Fea...

Page 5: ...cuit circuit breaker or fuse Make sure the product has an appropriate electrical ground to avoid the risk of electrocution or fire To eliminate unnecessary wear and improve its lifespan during periods...

Page 6: ...roduct securely to a rigging point whether an elevated platform or a truss When rigging the product onto a truss use a mounting clamp of appropriate weight capacity When power linking multiple product...

Page 7: ...ontrol panel functions using the four panel buttons located around the display Button Function MENU Access the menu Return to a previous menu option ENTER Select menu option Store the current menu or...

Page 8: ...R G B Auto Mode AUTO MODE SLAVE MODE MANUAL MODE DMX MODE ARTNET MODE Speed Program IP Address Subnet Mask Net Subnet Unive LED Pixel N Strip Flexible String D Pixel Strip Batten 440 Breath Led 3D Ba...

Page 9: ...rsion Press MENU to enter the menu Navigate to Software Version with UP or DOWN and press ENTER to confirm 5 3 Auto Mode The device starts running in Auto mode after connection to the mains This mode...

Page 10: ...f the master device to the DMX input of the first slave unit 5 5 Manual Mode Set manual mode which can adjust the RGB color 1 Press MENU to enter the menu 2 Navigate to Operation Mode with UP or DOWN...

Page 11: ...signal from controller is not connected with the input of the device the controller is switched off or defective if the cable or connector is defective or the signal wires are swap in the input conne...

Page 12: ...5 P10 Program 10 176 191 P11 Program 11 192 207 P12 Program 12 208 223 P13 Program 13 224 239 P14 Program 14 240 255 P15 Program 15 7 000 015 No function 016 031 P16 Program 1 032 047 P17 Program 2 04...

Page 13: ...0 1 002 0 0 255 for example a computer can be set to the address 002 0 0 X X you can set as 99 can also be the value of the other as long as don t setting the same with controller box 2 Subnet mask ca...

Page 14: ...ss range namely 0 255 Changes SubNet Mask Subnet mask can be 255 255 255 0 also can be set into 255 0 0 0 or 255 255 0 0 Gateway and must be consistent and DNS the first three Numbers also must agree...

Page 15: ...ocation of the connections Mechanically moving parts must not show any signs of wear and tear The electric power supply cables must not show any damage Have a qualified technician maintain the device...

Reviews: