4 D
OMINION
SX
I
NSTALLATION AND
O
PERATIONS
M
ANUAL
Hardware Installation
Figure 2 Rear Panel of 32-port single power supply model
Physical Installation of Dominion SX for Initial Configuration:
1.
Obtain a computer with a network card and crossover network cable. This computer will be referred to
as the ‘installation computer.’
2.
Physically mount the unit in an ergonomically sound manner. The unit is designed to be easily rack-
mounted, and rack mounting is recommended.
3.
Connect the crossover network LAN cable to the primary LAN connection on the back of the chassis.
Connect the other end to the network card in the installation computer.
4.
Connect the female end of the external power cord to the back of the chassis.
5.
Connect the male end of the external power cord to the power supply outlet. Power ON the Dominion
SX unit.
Note: The unit will perform a hardware and firmware self-test and then start the software boot sequence.
The boot sequence takes a short time and is complete when the light illuminates and remains on.
6.
Each unit comes with a certain set of configuration defaults henceforth referred to as Factory Reset
Mode. The default network settings for this mode are:
Internet Address (IP)
192.168.0.192
Gateway Address
192.168.0.192
Subnet Mask
255.255.255.0
Port Address
51000
Username admin
Password raritan
Figure 3 Default Settings for Factory Reset Mode
7.
Ensure that your installation computer can communicate with IP address 192.168.0.192. First, verify
that the installation computer has the route for 192.168.0.192:
a.
On the command line interface of the installation computer, enter the command
route print
.
b.
If 192.168.0.192 is on the gateway list, proceed to the next step. Otherwise, add 192.168.0.192 to
the gateway list: type the following commands into either a DOS or UNIX command line interface
on the installation computer where your browser is running:
i.
On a Windows NT/95/98/2000 system:
route add 192.168.0.192 <client_host IP address>
Example:
route add 192.168.0.192 15.128.122.12
ii.
On a UNIX (incl. Sun Solaris) system:
route add 192.168.0.192 <client_host IP address> -
interface
Primary LAN Connection
RJ45 serial ports
Modem
SelfTest and Factory Reset LED
Terminal/Factory Reset (RESERVED)
Summary of Contents for SX32
Page 2: ...This page intentionally left blank ...
Page 4: ...This page intentionally left blank ...
Page 78: ...68 DOMINION SX INSTALLATION AND OPERATIONS MANUAL ...
Page 90: ...80 DOMINION SX INSTALLATION AND OPERATIONS MANUAL ...
Page 94: ...84 DOMINION SX INSTALLATION AND OPERATIONS MANUAL ...
Page 102: ...92 DOMINION SX INSTALLATION AND OPERATIONS MANUAL ...
Page 106: ...96 DOMINION SX INSTALLATION AND OPERATIONS MANUAL ...
Page 108: ...98 DOMINION SX INSTALLATION AND OPERATIONS MANUAL ...
Page 122: ...112 DOMINION SX INSTALLATION AND OPERATIONS MANUAL ...
Page 134: ...124 DOMINION SX INSTALLATION AND OPERATIONS MANUAL ...
Page 174: ...164 DOMINION SX INSTALLATION AND OPERATIONS MANUAL ...
Page 177: ...APPENDIX J TECHNICAL FAQS 167 ...
Page 178: ...168 DOMINION SX INSTALLATION AND OPERATIONS MANUAL 255 60 2000 ...