T2P9D01 Mainboard

User's Guide

For System Configuration

and Set Up

 

© 2017 - 2018 Raptor Computing Systems, LLC

T2P9D01 User's Guide Version 1.04

All Rights Reserved

https://www.

 

 raptorcs.com

Summary of Contents for T2P9D01

Page 1: ...T2P9D01 Mainboard User s Guide For System Configuration and Set Up 2017 2018 Raptor Computing Systems LLC T2P9D01 User s Guide Version 1 04 All Rights Reserved https www raptorcs com...

Page 2: ...CIFICATIONS 8 MAINBOARD OVERVIEW 10 Design 10 Installation 11 Removal 11 CPU INSTALLATION AND REMOVAL 12 Background 12 Installation 13 Removal 15 RAM INSTALLATION AND REMOVAL 16 Population Tables 16 I...

Page 3: ...PGA Mode Switch 1 36 Chassis Intrusion Detect 37 FPGA Mode Switch 2 38 PM8068 SAS Debug Connector 39 5V Power 41 CPU 1 Secure Mode Disable 42 CPU 2 Secure Mode Disable 43 PMBus Connector 44 CPU EPS Po...

Page 4: ...m 63 BMC Access 64 Host Firmware Updates 64 BMC Firmware Updates 64 EARLY BOOT DEVICE FIRMWARE 66 Introduction 66 Installation 66 Removal 66 SUPPORT 68 Getting Help 68 ERRATA 69 PCB Version 1 00 69 PC...

Page 5: ...GES FOR LOSS OF PROFITS LOSS OF BUSINESS LOSS OF USE OR DATA INTERRUPTION OF BUSINESS AND THE LIKE EVEN IF RAPTOR COMPUTING SYSTEMS LLC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES ARISING FROM...

Page 6: ...power company If your power supply is not functioning do not attempt to repair it Contact a qualified service technician or your retailer OPERATIONAL SAFETY Before installing the motherboard or conne...

Page 7: ...television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocat...

Page 8: ...Total Slots 16 4 channels per CPU Capacity 2TB maximum Memory Type DDR4 1600 1866 2133 2400 2666 Memory Features ECC Module Sizes 8GB 16GB 32GB 64GB 128GB RDIMM Expansion Slots Total PCIe Slots 5 Tota...

Page 9: ...nvironmental Requirements Operation 10 C 35 C Storage 40 C 70 C Humidity 20 90 non condensing NOTE Specifications are subject to change without notice 2017 2018 Raptor Computing Systems LLC T2P9D01 Us...

Page 10: ...lity and large amounts of processing capability PCIe slots and peripherals are directly connected to each CPU therefore two CPUs must be installed to use all PCIe slots 2017 2018 Raptor Computing Syst...

Page 11: ...rque all mainboard mounting screws to 7 ft lbs 0 8N m WARNING There are fragile electronic components located on the entire bottom surface of the mainboard including near the mainboard mounting holes...

Page 12: ...e not vertical loosen the retention screw of the heatsink assembly and gently reposition the heatsink watching for the latching prongs to move into a vertical position NOTE Incorrectly positioned lock...

Page 13: ...in an appropriate anti static environment Carefully remove the protective cover making sure not to touch any of the exposed socket pins 2017 2018 Raptor Computing Systems LLC T2P9D01 User s Guide Ver...

Page 14: ...bly carefully center an indium pad on top of the CPU Place the heatsink assembly on top of the CPU following instructions given earlier 2017 2018 Raptor Computing Systems LLC T2P9D01 User s Guide Vers...

Page 15: ...erse Start with step 5 turning the hex driver counterclockwise and end with step 1 replacing the socket protective cover into postion over the socket WARNING Before attempting to remove the heatsink e...

Page 16: ...DIMMs X X X X 5 DIMMs X X X X X 6 DIMMs X X X X X X 7 DIMMs X X X X X X X 8 DIMMs X X X X X X X X 9 DIMMs X X X X X X X X X 10 DIMMs X X X X X X X X X X 11 DIMMs X X X X X X X X X X X 12 DIMMs X X X X...

Page 17: ...f memory is correct The T2P9D01 only accepts full size 288 pin DDR4 DIMMs and other types of memory will not seat or function DO NOT attempt to force a DIMM into a slot as this may cause permanent dam...

Page 18: ...even pins are on one side of the header and all odd pins are on the other Single row headers use a monotonically increasing pin number starting from pin 1 Key pins are not physically present but are s...

Page 19: ...an fail LED cathode 7 LED Anode 3 3V main power 8 Fan Fail LED Anode 5V main power 9 LED Anode 3 3V standby power 10 NIC 2 link activity LED cathode 11 LED Anode 3 3V standby power 12 NIC 1 link activ...

Page 20: ...HDD activity LED cathode 15 3 3V main power 16 Power LED cathode 17 KEY 18 KEY 19 NMI button active low 20 Ground 2017 2018 Raptor Computing Systems LLC T2P9D01 User s Guide Version 1 04 All Rights Re...

Page 21: ...E J7701 Pin Function Pin Function 1 DCD 2 RXD 3 TXD 4 DTR 5 Ground 6 DSR 7 RTS 8 CTS 9 NRI 10 KEY 2017 2018 Raptor Computing Systems LLC T2P9D01 User s Guide Version 1 04 All Rights Reserved https www...

Page 22: ...4 KEY 5 TPM reset active low 6 N C 7 LPC address data bit 3 8 LPC address data bit 2 9 3 3V main power 10 LPC address data bit 1 11 LPC address data bit 0 12 Ground 13 I2C clock 14 I2C data 2017 2018...

Page 23: ...y power 16 LPC serial IRQ 17 Ground 18 N C 19 Window open active low 20 BMC GPIO B3 active low 2017 2018 Raptor Computing Systems LLC T2P9D01 User s Guide Version 1 04 All Rights Reserved https www ra...

Page 24: ...Module presence detect 1 active low 7 Integrity loop 0 8 Integrity loop 0 9 LPC address data bit 3 secure 10 LPC address data bit 0 platform 11 LPC address data bit 2 secure 12 LPC address data bit 1...

Page 25: ...25 LPC reset active low secure 26 LPC reset active low platform 27 BMC SPI MOSI secure 28 BMC SPI clock platform 29 BMC SPI clock secure 30 BMC SPI MOSI platform 31 BMC SPI MISO secure 32 BMC SPI MIS...

Page 26: ...MODE J6912 Pin Function Pin Function 1 OCC alert active low 2 Ground current limited 2017 2018 Raptor Computing Systems LLC T2P9D01 User s Guide Version 1 04 All Rights Reserved https www raptorcs com...

Page 27: ...ERNAL RESET HEADER J7000 Pin Function Pin Function 1 N C 2 BMC reset active low 3 Ground 2017 2018 Raptor Computing Systems LLC T2P9D01 User s Guide Version 1 04 All Rights Reserved https www raptorcs...

Page 28: ...RY SERIAL HEADER J10116 Pin Function Pin Function 1 Ground 2 BMC COM2 RXD TTL 3 BMC COM2 TXD TTL 2017 2018 Raptor Computing Systems LLC T2P9D01 User s Guide Version 1 04 All Rights Reserved https www...

Page 29: ...EAT INDICATOR HEADER J10114 Pin Function Pin Function 1 Ground 2 BMC heartbeat LED cathode 2017 2018 Raptor Computing Systems LLC T2P9D01 User s Guide Version 1 04 All Rights Reserved https www raptor...

Page 30: ...3 SuperSpeed RX Port 4 positive polarity 4 Ground 5 SuperSpeed TX Port 4 negative polarity 6 SuperSpeed TX Port 4 positive polarity 7 Ground 8 Hub Port 1 negative polarity 9 Hub Port 1 positive polari...

Page 31: ...polarity 15 SuperSpeed TX Port 3 negative polarity 16 Ground 17 SuperSpeed RX Port 3 positive polarity 18 SuperSpeed RX Port 3 negative polarity 19 5 0V USB power current limited 20 KEY 2017 2018 Rap...

Page 32: ...MC I2C PORT 5 J9602 Pin Function Pin Function 1 BMC I2C SCL 2 Ground 3 BMC I2C SDA 2017 2018 Raptor Computing Systems LLC T2P9D01 User s Guide Version 1 04 All Rights Reserved https www raptorcs com 3...

Page 33: ...MC I2C PORT 6 J9603 Pin Function Pin Function 1 BMC I2C SCL 2 Ground 3 BMC I2C SDA 2017 2018 Raptor Computing Systems LLC T2P9D01 User s Guide Version 1 04 All Rights Reserved https www raptorcs com 3...

Page 34: ...ROGRAMMING HEADER J10104 Pin Function Pin Function 1 3 3V standby power 2 SCL 3 Ground 4 SDA 2017 2018 Raptor Computing Systems LLC T2P9D01 User s Guide Version 1 04 All Rights Reserved https www rapt...

Page 35: ...Function Pin Function 1 Ground 2 SPI clock 3 SPI MOSI 4 SPI MISO 5 SPI slave select active low 6 3 3V standby power 2017 2018 Raptor Computing Systems LLC T2P9D01 User s Guide Version 1 04 All Rights...

Page 36: ...E SWITCH 1 J7800 Pin Function Pin Function 1 Mode enable bit 1 active low pullup 2 Ground 2017 2018 Raptor Computing Systems LLC T2P9D01 User s Guide Version 1 04 All Rights Reserved https www raptorc...

Page 37: ...J9900 Pin Function Pin Function 1 Intrusion detect active low pullup 2 RTC battery 3 0V current limited 2017 2018 Raptor Computing Systems LLC T2P9D01 User s Guide Version 1 04 All Rights Reserved ht...

Page 38: ...SWITCH 2 J10109 Pin Function Pin Function 1 Mode enable bit 2 active low pullup 2 Ground 2017 2018 Raptor Computing Systems LLC T2P9D01 User s Guide Version 1 04 All Rights Reserved https www raptorc...

Page 39: ...main power 2 UART TX Port 0 3 UART TX Port 1 4 UART RX Port 0 5 UART RX Port 1 6 Ground 7 Reset active low 8 JTAG TDI 9 JTAG TMS 10 JTAG TCLK 2017 2018 Raptor Computing Systems LLC T2P9D01 User s Gui...

Page 40: ...11 JTAG reset active low 12 JTAG TDO 2017 2018 Raptor Computing Systems LLC T2P9D01 User s Guide Version 1 04 All Rights Reserved https www raptorcs com 40...

Page 41: ...5V POWER J19511 Pin Function Pin Function 1 5V main power 2 Ground 3 Ground 2017 2018 Raptor Computing Systems LLC T2P9D01 User s Guide Version 1 04 All Rights Reserved https www raptorcs com 41...

Page 42: ...1600 Pin Function Pin Function 1 N C 2 Secure Mode Disable active high 3 1 1V standby power current limited 2017 2018 Raptor Computing Systems LLC T2P9D01 User s Guide Version 1 04 All Rights Reserved...

Page 43: ...4300 Pin Function Pin Function 1 N C 2 Secure Mode Disable active high 3 1 1V standby power current limited 2017 2018 Raptor Computing Systems LLC T2P9D01 User s Guide Version 1 04 All Rights Reserved...

Page 44: ...Pin Function Pin Function 1 I2C SCL 2 I2C SDA 3 Alert active low open drain 4 Ground 5 3 3V main power 2017 2018 Raptor Computing Systems LLC T2P9D01 User s Guide Version 1 04 All Rights Reserved htt...

Page 45: ...Pin Function 1 Ground 2 Ground 3 Ground 4 Ground 5 12V EPS main power 6 12V EPS main power 7 12V EPS main power 8 12V EPS main power 2017 2018 Raptor Computing Systems LLC T2P9D01 User s Guide Version...

Page 46: ...r 2 3 3V main power 3 Ground 4 5 0V main power 5 Ground 6 5 0V main power 7 Ground 8 ATX power good active high 9 5 0V standby power 10 12V main power 2017 2018 Raptor Computing Systems LLC T2P9D01 Us...

Page 47: ...15 Ground 16 ATX power enable active low 17 Ground 18 Ground 19 Ground 20 No connection 21 5 0V main power 22 5 0V main power 23 5 0V main power 24 Ground 2017 2018 Raptor Computing Systems LLC T2P9D0...

Page 48: ...B1 12V main power A2 12V main power B2 12V main power A3 12V main power B3 12V main power A4 Ground B4 Ground A5 JTAG TCK N C pull down B5 SMBus Clock 2017 2018 Raptor Computing Systems LLC T2P9D01 U...

Page 49: ...Lane 1 TX N A21 Lane 1 RX N B21 Ground A22 Lane 1 RX P B22 Ground A23 Ground B23 Lane 2 TX P A24 Ground B24 Lane 2 TX N A25 Lane 2 RX N B25 Ground A26 Lane 2 RX P B26 Ground A27 Ground B27 Lane 3 TX P...

Page 50: ...8 Lane 10 TX P A59 Ground B59 Lane 10 TX N A60 Lane 10 RX N B60 Ground A61 Lane 10 RX P B61 Ground A62 Ground B62 Lane 11 TX P A63 Ground B63 Lane 11 TX N A64 Lane 11 RX N B64 Ground A65 Lane 11 RX P...

Page 51: ...B79 Lane 15 TX N A80 Lane 15 RX N B80 Ground A81 Lane 15 RX P B81 Presence detect active low A82 Ground B82 Reserved N C 2017 2018 Raptor Computing Systems LLC T2P9D01 User s Guide Version 1 04 All Ri...

Page 52: ...CPU 2 PCI EXPRESS SLOTS 2017 2018 Raptor Computing Systems LLC T2P9D01 User s Guide Version 1 04 All Rights Reserved https www raptorcs com 52...

Page 53: ...k P B13 Ground A14 Differential clock N B14 Lane 0 TX P A15 Ground B15 Lane 0 TX N A16 Lane 0 RX N B16 Ground A17 Lane 0 RX P B17 Presence detect active low A18 Ground B18 Ground A19 Reserved N C B19...

Page 54: ...ound B49 Ground A50 Reserved N C B50 Lane 8 TX P A51 Ground B51 Lane 8 TX N A52 Lane 8 RX N B52 Ground A53 Lane 8 RX P B53 Ground A54 Ground B54 Lane 9 TX P A55 Ground B55 Lane 9 TX N A56 Lane 9 RX N...

Page 55: ...P A75 Ground B75 Lane 14 TX N A76 Lane 14 RX N B76 Ground A77 Lane 14 RX P B77 Ground A78 Ground B78 Lane 15 TX P A79 Ground B79 Lane 15 TX N A80 Lane 15 RX N B80 Ground A81 Lane 15 RX P B81 Presence...

Page 56: ...on A1 3 3V main power B1 N C reserved A2 Ground B2 Ground A3 Lane 0 RX P B3 Lane 0 TX P A4 Lane 0 RX N B4 Lane 0 TX N A5 Ground B5 Ground 2017 2018 Raptor Computing Systems LLC T2P9D01 User s Guide Ve...

Page 57: ...3 Presence detect active low B13 Differential clock N A14 Ground B14 Ground A15 Lane 2 RX N B15 Lane 2 TX P A16 Lane 2 RX P B16 Lane 2 TX N A17 Ground B17 Ground A18 Lane 3 RX P B18 Lane 3 TX P A19 La...

Page 58: ...DER J7905 Pin Function Pin Function 1 Ground 2 12V main power 3 Tachometer input 4 PWM output 2017 2018 Raptor Computing Systems LLC T2P9D01 User s Guide Version 1 04 All Rights Reserved https www rap...

Page 59: ...DER J7904 Pin Function Pin Function 1 Ground 2 12V main power 3 Tachometer input 4 PWM output 2017 2018 Raptor Computing Systems LLC T2P9D01 User s Guide Version 1 04 All Rights Reserved https www rap...

Page 60: ...J7900 J7901 J7902 J7903 Pin Function Pin Function 1 Ground 2 12V main power 3 Tachometer input 4 PWM output 2017 2018 Raptor Computing Systems LLC T2P9D01 User s Guide Version 1 04 All Rights Reserve...

Page 61: ...AN HEADER J10110 Pin Function Pin Function 1 Ground 2 12V main power 3 Tachometer input 4 PWM output 2017 2018 Raptor Computing Systems LLC T2P9D01 User s Guide Version 1 04 All Rights Reserved https...

Page 62: ...s in each zone is tested If any zone lacks at least one connected or functional fan an alert will be set for that zone and all fans within the zone will be set to full speed The CPU fans have addition...

Page 63: ...ccess press the power button on your chassis Within a few seconds the system should initiate the IPL cycle and in about 10 seconds the front panel will start showing IPL status information on the ID N...

Page 64: ...to request an IP address via DHCP Once it is connected and has a valid IP address you can log in via SSH using the following default credentials Username root Password 0penBmc NOTE It is strongly rec...

Page 65: ...during any BMC firmware update there is a possibility that the update process may result in a non functional BMC Recovery of the BMC in this situation would requiring external programming of the socke...

Page 66: ...re Execute the JFFS2 image creation command as follows mkfs jffs2 r tmp firmware o tmp firmware_jffs_image bin Save the generated firmware_jffs_image bin file in a location accessible from the main bo...

Page 67: ...pflash P BOOTKERNFW E 2017 2018 Raptor Computing Systems LLC T2P9D01 User s Guide Version 1 04 All Rights Reserved https www raptorcs com 67...

Page 68: ...ectly at support raptorcs com Alternatively we also have a Wiki and other support resources available online at https www raptorcs com the information you require may already be available on one of th...

Page 69: ...e to the on board control FPGA while in power state S5 An internal ring oscillator may be used to work around this limitation PCB VERSION 1 01 ER0001 PCIe connector J10108 is incorrectly identified as...

Reviews: