of explosives and narcotics in vapor mode. Select the split window in plasmagram view because explosives and
narcotics are detected in vapor mode.
Enables you to print data and configuration files.
NOTE:
You must have a PCL 3.0 or lower compliant printer for the Print function.
1. Select Menu > Print.
Figure 4-36
Print Dialog
The data automatically prints to your default local or network printer. To print to a specific local or network
printer, check
Show Printer Options.
2. Press the appropriate option.
Function
Description
Print Data & Config
Prints the plasmagram with peaks, peaks found list, any substances detected, and the device and
substance configuration.
Print Data
Prints the plasmagram with peaks, peaks found list, and any substances detected.
Print Config
Prints the device and substance configuration.
Table 4-8
Printing Dialog
•
If you did not check
Show Printer Options
, the data prints to the default local or network printer.
NOTE:
If you are printing to a network printer, the
Logon to Network Server
screen displays. Enter your
information in the
User Name
,
Password
, and
Domain
fields. Press OK.
•
If you checked
Show Printer Options
, the
screen displays.
CHAPTER 4 │User's Guide
81
Rapiscan Systems Proprietary and Confidential
Summary of Contents for Mobile Trace
Page 1: ...MobileTrace User s Guide For P0007027 MA001133 Revision ...
Page 2: ......
Page 31: ...This page intentionally left blank to ensure new chapters start on right odd number pages ...
Page 60: ...CHAPTER 4 Menu Functions Main Screen 44 Menu Functions 45 ...
Page 164: ...CHAPTER 9 Parts and Accessories Device and Replacement Part Numbers 148 ...
Page 167: ...This page intentionally left blank to ensure new chapters start on right odd number pages ...
Page 178: ...For P0007027 MA001133 Revision C ...