
18
English
GA 110 E
Special Cast-Iron Gas Heating and Hot Water Boiler with
Electronic Ignition
Installation Manual
Table of Contents
Symbols and Warning indications . . . . . . . . . . . . . . . 18
1 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
2 Regulations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
3 Guarantee . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
4 Package contents of delivery . . . . . . . . . . . . . . . . . . 19
5 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
6 Technical specifications . . . . . . . . . . . . . . . . . . . . . . 21
7 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
7.1 Boiler room . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
7.2 Connections on heater side . . . . . . . . . . . . . . . 22
7.3 Gas installation . . . . . . . . . . . . . . . . . . . . . . . . . 22
7.4 Waste gas connection . . . . . . . . . . . . . . . . . . . . 22
8 Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
8.1 Boiler sensor connection
(accessory) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
8.2 Rapidomatic control connection
(accessory) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
8.3 Room clock thermostat RTU
(accessory) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
8.4 Remote control connection for comfortmatic
(accessory) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
9 Gas setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
9.1 Appliance check . . . . . . . . . . . . . . . . . . . . . . . . 26
9.2 Gas setting according to air vent pressure
method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
9.3 Gas setting according to volumetric method . . . 26
9.4 Gas flow pressure inspection . . . . . . . . . . . . . . 27
9.5 Functional check . . . . . . . . . . . . . . . . . . . . . . . . 27
9.6 Conversion to alternative gas type
Gas settings table . . . . . . . . . . . . . . . . . . . . . . . 27
10 Initial operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
10.1 Function monitoring . . . . . . . . . . . . . . . . . . . . . . 28
10.2 Releasing the safety temperature limiter STB . 28
10.3 Unlocking the waste gas monitor . . . . . . . . . . . 28
11 Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
11.1 Shutting down the installation . . . . . . . . . . . . . . 29
11.2 Danger of freezing . . . . . . . . . . . . . . . . . . . . . . . 29
12 Upkeep and maintenance . . . . . . . . . . . . . . . . . . . . . 30
13 Operating the control panel . . . . . . . . . . . . . . . . . . . . 31
14 Trouble shooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
15 Circuit diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Warning indications and symbols
In this installation manual the following descriptions or
symbols are used for particularly important indications.
Instructions and prohibitions for the prevention of
personal injury or serious damage.
Instructions for work on the electrical installation
Tips for environmental protection
☞
Tips for economical use or simpler operation.
How to proceed when gas is smelt.
– It is absolutely necessary to avoid sparks or open fire!
Do not smoke and avoid the use of electrical
appliances such as telephone, doorbell, light switch,
etc..
– Shut off main gas supply.
– Open windows and doors for ventilation.
– Warn all other occupants and evacuate the building.
– Contact your local gas supply company or your dealer.
How to proceed when waste gas is smelt
– Switch off the installation. Set main switch into „off“
position.
– Open windows and doors to allow ventilation.
– Contact your dealer.
Further warning indications
– Do not store or use explosive or (highly) inflammable
substances (such as petrol, paints, paper, etc.) in the
boiler room.
– Do not carry out any modifications on the heating unit,
fittings, or the actual construction.
– Aggressive chemical substances in the combustion air
may cause corrosion to the burner or the waste gas
system. This would result in reduced burner life. This
is why the boiler room should be free from solvents,
paints, glues, sprays, washing powder, etc.