background image

Compact Fire Fighters by Rapid Spray

Rapid Spray Fire Marshal Operators Handbook

14

KAWASHIMA FIRE PUMP CONT.

OPERATION - THROTTLE LEVER

Pump output is controlled by adjusting the throttle lever. At maximum throttle position, 

the pump will deliver the highest output volume. Moving the throttle level toward the idle 

position will decrease the output volume of the pump.

OPERATION - STOPPING ENGINE

1. 

Lower the throttle level fuly and cool the engine down for 1-2 minutes at low speed.

2. 

Press the stop button to stop the engine running.

T

H

L

T - Throttle Level

H - MAXIMUM

L - IDLE

STOP BUTTON

STOP BUTTON

NOTE.

 Stop the engine immediately in the event of an emergency.

Summary of Contents for FIRE MARSHAL

Page 1: ...FIREMARSHAL OPERATORS HANDBOOK Fire Fighting FIRE MARSHAL FIRE MARSHAL PLUS 250L 325L...

Page 2: ...els 02 Warnings 03 Product Risk Assessment 04 Troubleshooting 05 Operation 05 Before Beginning Operation 05 Operation 06 Honda GX35 Engine 12 Kawashima Fire Pump 15 Cleaning Maintenance 17 Fire Marsha...

Page 3: ...esign may change slightly from what is shown in this operators handbook WARNING Always obey vehicle and UTV ATV manufacturer instructions regarding loading and operation Please check weight restrictio...

Page 4: ...ther mental capacity 4 Improper or careless use of this unit can cause serious injury Minors should never be allowed to use this unit This unit should not be used when bystanders or animals are in the...

Page 5: ...niques don t lift on your own if 20kg bend knees and keep back straight Mix chemicals if applicable and fill fire fighting unit As above spray drift chemical spillage emission of vapours or flammabili...

Page 6: ...drops fluctuates during standard operation 1 Restriction on suction line 2 Pump sucking air 3 Plugged filter 4 Damaged regulator 1 Inspect tank and suction lines and remove restriction 2 Tighten fitti...

Page 7: ...upplied with the unit and ensure you follow all warnings and instructions contained within WARNING Motor is shipped without oil or fuel Before operation fill the motor with the correct oil and fuel as...

Page 8: ...controls and learn how to stop the engine quickly in case of emergency Make sure the operator receives adequate instruction before operating the equipment Do not allow children to operate the engine K...

Page 9: ...P DIPSTICK ENGINE CONTROLS CHOKE LEVER THROTTLE LEVER THROTTLE LEVER ENGINE SWITCH GX25 GX35 Applicable Types Centrifugal Clutch The centrifugal clutch automatically engages and transmits power when e...

Page 10: ...e is level and the engine switch is in the OFF position Always check the following items before you start the engine Check the General Condition of the Engine 1 Look around and underneath the engine f...

Page 11: ...ith engine startup shutdown or operation STARTING THE ENGINE Refer to the instructions provided with the equipment for throttle lever and engine switch 1 To start a cold engine move the choke lever 1...

Page 12: ...ING THE ENGINE cont HONDA GX35 ENGINE CONT 4 Pull the start grip 4 lightly until you feel resistance then pull briskly in the direction of the arrow 5 Return the starter grip gently Notice Do not allo...

Page 13: ...y 1 Turn the engine siwtch to OFF O B position 2 Move the choke lever to the OPEN position 3 Hold the throttle level 6 on the equipement in the MAX B position 4 Pull the starter grip 3 to 5 times Foll...

Page 14: ...l medicinal liquids or caustic liquids such as used oil wine or polluted water To prevent fire hazards and to provide adequate ventilation keep the pump at least 1 meter 3 feet away from building wall...

Page 15: ...l occur NOTE Discharge port angle can be changed to 3 different directions Adjust to your operating condition 4 Submerge the suction hose strainer in the water 5 Remove self suction plug and top up th...

Page 16: ...ump will deliver the highest output volume Moving the throttle level toward the idle position will decrease the output volume of the pump OPERATION STOPPING ENGINE 1 Lower the throttle level fuly and...

Page 17: ...engine Clean the air filter regularly particularly if working in a dusty environment Clean and adjust the spark plug as necessary Clean the cooling fan air intake opening and parts around the muffler...

Page 18: ...ifications Daily Inspect the fuel line and filter check for leaks or contamination Weekly Clean air filter in accordance with engine manufacturers instructions see engine tab As needed Replace engine...

Page 19: ...d the Honda Engine Operators Instruction Manual and Warranty Policy All repairs should be carried out by a licensed Honda dealer or maintenance shop or by any engine repair establishment or individual...

Page 20: ...ription 1 AMPTC00200ATT 400BTT 1 200 400L Marshal Tank 2 3 4 ARLP250VSR 1 255mm Screw Lid 5 AMAXPM010BK 1 10L Rinse Tank only Marshal Plus units 6 7 CFNB20M 1 3 4 poly Drain Bun Seal 8 CFVTB20M 1 3 4...

Page 21: ...25F1 Back end brass nut 6 CFBL25F2 Swivel end brass nut for hose reel 7 CFPPT25M220 25 220mm screw pipe piece poly 8 CHJCH01X100X30 Spring for FF hose reel 9 CUF14519MMX36N 36m length x 19mm fire hose...

Page 22: ...ers in excess of the obligations of RAPID SPRAY expressly set forth herein NOTE All tank and spray systems must have their warranty activated by returning warranty card located at the end of this docu...

Page 23: ...ons damaged by corrosive chemicals dirt and sand excessive heat moisture or other environmental impacts Warranty determination on these type of failures will be made by RAPID SPRAY only after inspecti...

Page 24: ...Compact Fire Fighters by Rapid Spray Rapid Spray Fire Marshal Operators Handbook 22 This page has been left blank intentionally...

Page 25: ...own Purchaser s Name Purchaser s Address Purchaser s Phone Number Email Address Disclaimer If you don t want us to keep you informed of new products please tick the following circle To help us help yo...

Page 26: ...Compact Fire Fighters by Rapid Spray Rapid Spray Fire Marshal Operators Handbook 24 This page has been left blank intentionally...

Page 27: ...JUN 2023 Rapid Spray Fire Marshal Operators Handbook 25 AYH013 NOTES...

Page 28: ...Compact Fire Fighters by Rapid Spray Rapid Spray Fire Marshal Operators Handbook 26 NOTES...

Page 29: ...JUN 2023 Rapid Spray Fire Marshal Operators Handbook 27 AYH013 NOTES...

Page 30: ...s on 1800 011 000 or visit www rapidspray net 35 Enterprise Cres Singleton NSW 2330 PO BOX 3119 Singleton NSW 2330 Telephone 1800 011 000 Facsimile 02 6571 2951 Rapid Spray Liquid Management Systems A...

Reviews: