Cable and Antenna Test Mode
R&S
®
ZNH
118
User Manual 1334.5985.02 ─ 02
Using markers
In addition to the standard marker functionality, the following features several extended
marker output formats.
Table 7-1: Extended marker output format
Marker output format
Descriptions
"Normal"
Shows the marker value in current trace format.
"dB Mag Phase"
Shows the magnitude (in dB) and the phase at the current marker posi-
tion.
"Lin Mag Phase (Rho)"
Shows the converted magnitude (in %) and the phase (in rho) at the cur-
rent marker position.
"Real + Imag (Rho)"
Shows the real and imaginary components at the current marker posi-
tion.
"R + jX"
Shows the real and imaginary components of the impedance at the
marker position. The imaginary component is converted to inductance or
capacitance. Marker frequency and sign are taken into account.
"G + jB"
Shows the real and imaginary components of the admittance at the
marker position. The imaginary component is converted to inductance or
capacitance. Marker frequency and sign are taken into account.
"SWR"
Shows the standing wave ratio at current marker position.
"Delay"
Shows the group delay at the current marker position.
► Press [MARKER] key.
The R&S
ZNH activates a marker and opens the marker softkey menu. Like usual
traces, you can move the marker around with the rotary knob or enter a specific
marker position.
Performing Cable and Antenna Measurements