[:SOURce<hw>]:IQ:IMPairment[:STATe]
.......................................................................... 726
...........................................................................................726
..............................................................................................726
................................................................................. 727
..........................................................................................727
............................................................................................ 727
[:SOURce<hw>]:IQ:CREStfactor
<CrestFactor>
Sets the crest factor of the external analog signal.
Parameters:
<CrestFactor>
float
Range:
0 to 35
Increment: 0.01
*RST:
0
Default unit: dB
Example:
IQ:CRES 10
specifies a crest factor of 10 dB for the external analog signal.
Manual operation:
See
[:SOURce<hw>]:IQ:GAIN
<Gain>
Sets the baseband gain for the external analog wideband I/Q signal. Thus, the modula-
tion of the I/Q modulator can be optimized for any measurement requirement. The gain
settings for an internal or external baseband signal are performed with command
SOUR:BB:IQGain
.
Parameters:
<Gain>
DBM3 | DB0 | DB3 | DB6 | AUTO
DBM3
Activates 0 dB gain.
With this setting, signal distortions are minimized.
DB0
Activates 0 dB gain (standard settings).
DB3
Activates 0 dB gain.
This setting is recommended for 3GPP signals with very high
adjacent channel power ratio (ACPR).
DB6
Activates 0 dB gain.
With this setting, signal noise is minimized.
*RST:
DB3
Example:
IQ:SOUR ANAL
selects an external analog signal as the input signal for the I/Q
modulator. The signal must be applied at the inputs I and Q.
SOURce Subsystem
Summary of Contents for SMJ100A
Page 34: ...Preface R S SMJ100A 18 Operating Manual 1403 7458 32 14 Notes on Screenshots...
Page 86: ...Preparing for Use R S SMJ100A 70 Operating Manual 1403 7458 32 14 LXI Configuration...
Page 826: ...Remote Control Commands R S SMJ100A 810 Operating Manual 1403 7458 32 14 UNIT Subsystem...
Page 828: ...Maintenance R S SMJ100A 812 Operating Manual 1403 7458 32 14 Storing and Packing...
Page 844: ...Hardware Interfaces R S SMJ100A 828 Operating Manual 1403 7458 32 14 BERT Connector...