![R&S SMJ100A Operating Manual Download Page 710](http://html1.mh-extra.com/html/rands/smj100a/smj100a_operating-manual_3086611710.webp)
Remote Control Commands
R&S
®
SMJ100A
694
Operating Manual 1403.7458.32 ─ 14
[:SOURce<hw>]:BB:MEASurement:POWer:RMS?
Queries the power of the baseband signal relative to full scale of 0.5 V (in terms of dB
full scale) during measurement.
Return values:
<Rms>
float
Range:
-100 to 10
Increment: 0.01
*RST:
0
Default unit: dBfs
Example:
BB:MEAS:POW:RMS?
Queries the power of the baseband signal.
Usage:
Query only
Manual operation:
See
"Power - Digital Impairments - Measurement"
[:SOURce<hw>]:BB:MEASurement:RTIMe?
Queries the remaining time until the measurement of the digital I/Q baseband signal is
completed.
Return values:
<RTime>
string | hh:mm:ss
Example:
BB:MEAS:RTIM?
Queries the remaining measurement duration.
Usage:
Query only
Manual operation:
See
"Remaining Time - Digital Impairments - Measurement"
[:SOURce<hw>]:BB:MEASurement:SOURce
<Source>
Selects the signal source for the measurement. The power and crest factor can be
retrieved either from the interference-free digital I/Q baseband signal or the signal
superimposed by the noise generator AWGN.
Parameters:
<Source>
BB | BAWGn
BB
(Baseband Signal without AWGN)
Selects the measurement of the interference-free baseband sig-
nal.
BAWGn
(Baseband with AWGN)
Selects the measurement of the baseband signal after an
AWGN noise signal is added.
*RST:
BB
SOURce Subsystem
Summary of Contents for SMJ100A
Page 34: ...Preface R S SMJ100A 18 Operating Manual 1403 7458 32 14 Notes on Screenshots...
Page 86: ...Preparing for Use R S SMJ100A 70 Operating Manual 1403 7458 32 14 LXI Configuration...
Page 826: ...Remote Control Commands R S SMJ100A 810 Operating Manual 1403 7458 32 14 UNIT Subsystem...
Page 828: ...Maintenance R S SMJ100A 812 Operating Manual 1403 7458 32 14 Storing and Packing...
Page 844: ...Hardware Interfaces R S SMJ100A 828 Operating Manual 1403 7458 32 14 BERT Connector...