Remote Control Commands
R&S
®
SMJ100A
599
Operating Manual 1403.7458.32 ─ 14
Parameters:
<Spacing>
float
Range:
0.0 to 120E6
Increment: 0.01
*RST:
0
Default unit: Hz
Example:
BB:ARB:MCAR:CARR:SPAC 10 MHz
sets a carrier spacing of 10 MHz.
Manual operation:
See
[:SOURce<hw>]:BB:ARBitrary:MCARrier:CARRier<ch>:CONFlict?
Queries carrier conflicts. A conflict arises when the carriers overlap.
Return values:
<Conflict>
0 | 1 | OFF | ON
*RST:
0
Example:
BB:ARB:MCAR:CARR2:CONF?
queries the multi carrier conflict state.
Response:
0
no conflict has occurred.
Usage:
Query only
Manual operation:
See
[:SOURce<hw>]:BB:ARBitrary:MCARrier:CARRier<ch>:DELay
<Delay>
Sets the start delay of the selected carrier.
Parameters:
<Delay>
float
Range:
0 to 1
Increment: 1E-9
*RST:
0
Default unit: s
Example:
BB:ARB:MCAR:CARR15:DEL 5us
sets a start delay of 50 us for carrier 15.
Manual operation:
See
[:SOURce<hw>]:BB:ARBitrary:MCARrier:CARRier<ch>:FILE
<File>
Selects the file with I/Q data to be modulated onto the selected carrier.
Parameters:
<File>
<file name>
SOURce Subsystem
Summary of Contents for SMJ100A
Page 34: ...Preface R S SMJ100A 18 Operating Manual 1403 7458 32 14 Notes on Screenshots...
Page 86: ...Preparing for Use R S SMJ100A 70 Operating Manual 1403 7458 32 14 LXI Configuration...
Page 826: ...Remote Control Commands R S SMJ100A 810 Operating Manual 1403 7458 32 14 UNIT Subsystem...
Page 828: ...Maintenance R S SMJ100A 812 Operating Manual 1403 7458 32 14 Storing and Packing...
Page 844: ...Hardware Interfaces R S SMJ100A 828 Operating Manual 1403 7458 32 14 BERT Connector...