![R&S SMJ100A Operating Manual Download Page 604](http://html1.mh-extra.com/html/rands/smj100a/smj100a_operating-manual_3086611604.webp)
Remote Control Commands
R&S
®
SMJ100A
588
Operating Manual 1403.7458.32 ─ 14
Example:
BB:ARB:SEQ SING
sets trigger mode Single.
BB:ARB:TRIG:SLUN SEQ
sets unit Sequence length for the entry of sequence length.
BB:ARB:TRIG:SLEN 2
sets a sequence length of 2 waveforms. The current waveforms
will be output twice after the next trigger event.
Manual operation:
See
[:SOURce<hw>]:BB:ARBitrary:TRIGger:SMODe
<SMode>
The command selects the extended trigger mode for multi segment waveforms.
Parameters:
<SMode>
SAME | NEXT | NSEam | SEQuencer
NSEam = Next Segment Seamless
*RST:
NEXT
Example:
SOUR:BB:ARB:SEQ AUTO
selects trigger mode AUTO.
SOUR:BB:ARB:TRIG:SMOD SAME
the same segment of the waveform is output repeatedly.
Manual operation:
See
[:SOURce<hw>]:BB:ARBitrary:TRIGger:SOURce
<Source>
Selects the trigger source.
Parameters:
<Source>
INTernal|BEXTernal|EXTernal
INTernal
manual trigger or
*TRG
.
EXTernal|BEXTernal
trigger signal on the TRIGGER 1/2 connector.
*RST:
INTernal
Example:
SOURce1:BB:ARBitrary:TRIGger:SOURce EXTernal
sets external triggering via the TRIGGER 1 connector.
Manual operation:
See
[:SOURce<hw>]:BB:ARBitrary:TRIGger:DELay:UNIT
<TrigDelUnit>
Determines the units the trigger delay is expressed in.
Parameters:
<TrigDelUnit>
SAMPle | TIME
*RST:
SAMPle
Manual operation:
See
SOURce Subsystem
Summary of Contents for SMJ100A
Page 34: ...Preface R S SMJ100A 18 Operating Manual 1403 7458 32 14 Notes on Screenshots...
Page 86: ...Preparing for Use R S SMJ100A 70 Operating Manual 1403 7458 32 14 LXI Configuration...
Page 826: ...Remote Control Commands R S SMJ100A 810 Operating Manual 1403 7458 32 14 UNIT Subsystem...
Page 828: ...Maintenance R S SMJ100A 812 Operating Manual 1403 7458 32 14 Storing and Packing...
Page 844: ...Hardware Interfaces R S SMJ100A 828 Operating Manual 1403 7458 32 14 BERT Connector...