Remote Control Commands
R&S
®
SMJ100A
516
Operating Manual 1403.7458.32 ─ 14
Parameters:
<DEnable>
OFF | LOW | HIGH
OFF
Any signal at the
Data Enable
input is ignored; all data at the
BERT data input is used for the measurement.
HIGH
The
Data Enable
signal is used. The only data measured is the
data at the BERT data input during a high level of the
Data
Enable
signal. The measurement is interrupted during a low
level of the
Data Enable
signal.
LOW
The
Data Enable
signal is used. The only data measured is the
data at the BERT data input during a low level of the
Data
Enable
signal. The measurement is interrupted during a high
level of the
Data Enable
signal.
*RST:
OFF
Example:
BERT:SET:DEN HIGH
The measurement is interrupted during the low level of the
Data
Enable
input.
Manual operation:
See
:BERT:SETup:IGNore
<Ignore>
Activates/deactivates ignoring of pure "0" or "1" bit sequences at least 32 bits long.
Activating excludes faulty frames from the measurement. In the case of some mobile
radio standards, pure "0" or "1" bit sequences are generated when errors (e.g. an
incorrect checksum) are detected within a frame. These sequences, instead of the
frame data, are provided for the BER measurement and signal that the frame in ques-
tion should not be used for the measurement.
Parameters:
<Ignore>
OFF | ZERO | ONE
OFF
Pattern Ignore is not active.
ONE
Bit sequences consisting of 32 or more consecutive "1" data are
not used (i.e. ignored) for the BER mesaurement.
ZERO
Bit sequence consisting of 32 or more consecutive "0" data are
not used (i.e. ignored) for the BER measurement.
*RST:
OFF
Example:
BERT:SET:IGN ONE
specifies that bit sequences of "1" data at least 32 bits long are
not used for the measurement.
Manual operation:
See
BERT and BLER Subsystems
Summary of Contents for SMJ100A
Page 34: ...Preface R S SMJ100A 18 Operating Manual 1403 7458 32 14 Notes on Screenshots...
Page 86: ...Preparing for Use R S SMJ100A 70 Operating Manual 1403 7458 32 14 LXI Configuration...
Page 826: ...Remote Control Commands R S SMJ100A 810 Operating Manual 1403 7458 32 14 UNIT Subsystem...
Page 828: ...Maintenance R S SMJ100A 812 Operating Manual 1403 7458 32 14 Storing and Packing...
Page 844: ...Hardware Interfaces R S SMJ100A 828 Operating Manual 1403 7458 32 14 BERT Connector...