![R&S SMCVB-K161 User Manual Download Page 63](http://html1.mh-extra.com/html/rands/smcvb-k161/smcvb-k161_user-manual_3084628063.webp)
Remote-Control Commands
R&S
®
SMCVB-K161
63
User Manual 1179.1035.02 ─ 02
Example:
See
Example "Configure coding network properties"
Manual operation:
See
[:SOURce<hw>]:BB:ATSM:BURY:RATio
<MarketID>
Sets the power with that the watermark is added to the payload signal.
Parameters:
<MarketID>
DB21 | DB24 | DB27 | DB30 | DB33 | DB36 | DB39
*RST:
DB30
Example:
See
Example "Configure coding network properties"
Manual operation:
See
[:SOURce<hw>]:BB:ATSM:TRANsmission
<Transmission>
Enables/disables
transmission.
Parameters:
<Transmission>
0 | 1 | OFF | ON
*RST:
0
Example:
See
Example "Configure coding network properties"
Manual operation:
See
[:SOURce<hw>]:BB:ATSM:MTXid:TID
<TransmitterID>
Sets the transmitter ID for the MTXID transmission.
Parameters:
<TransmitterID>
integer
Range:
0 to 31
*RST:
0
Example:
See
Example "Configure coding network properties"
Manual operation:
See
[:SOURce<hw>]:BB:ATSM:MTXid:MID
<MarketID>
Sets the market ID for the transmission.
Parameters:
<MarketID>
integer
Range:
0 to 511
*RST:
0
Example:
See
Example "Configure coding network properties"
Manual operation:
See
Coding Commands