![R&S SMCVB-K161 User Manual Download Page 55](http://html1.mh-extra.com/html/rands/smcvb-k161/smcvb-k161_user-manual_3084628055.webp)
Remote-Control Commands
R&S
®
SMCVB-K161
55
User Manual 1179.1035.02 ─ 02
PBIN
PRBS before interleaver.
Pure pseudo-random bit sequence (PRBS) data used as modu-
lation data with no packet structure. PRBS data conforms with
specification.
PBET
PRBS before trellis.
Pure pseudo-random bit sequence (PRBS) data used as modu-
lation data with no packet structure and interleaving. Modulation
data is directly fed to the trellis encoder.
PBEM
PRBS before mapper
Pure pseudo-random bit sequence (PRBS) data directly fed to
the mapper.
Three bits at a time in two's complement are assigned to the
stages -7, -5, -3, -1, 1, 3, 5, 7. Subsequent pilot insertion and
VSB filtering remain unaffected.
*RST:
TTSP
Example:
See
Example "Configure test signal properties"
Manual operation:
See
[:SOURce<hw>]:BB:ATSM:TSPacket
<TsPacket>
Specifies the structure of the test transport stream packet that is fed to the modulator.
Parameters:
<TsPacket>
H184 | S187
*RST:
H184
Example:
See
Example "Configure test signal properties"
Manual operation:
See
[:SOURce<hw>]:BB:ATSM:PIDTestpack
<PIDTestpack>
If a header is present in the test packet ("Test TS Packet > Head/184 Payload"), you
can specify a fixed or variable packet identifier (PID).
Parameters:
<PIDTestpack>
NULL | VARiable
*RST:
NULL
Example:
See
Example "Configure test signal properties"
Manual operation:
See
[:SOURce<hw>]:BB:ATSM:PID
<PID>
.
Input Signal Commands