Remote Control Commands
R&S
®
SGT100A
399
User Manual 1176.8674.02 ─ 07
Usage:
Event
Manual operation:
See
[:SOURce<hw>]:BB:ARBitrary:WSEGment:NEXT:SOURce
<Source>
Selects the next segment source, i.e. determines whether the next segment is
switched upon receiving of an external trigger signal or upon executing of software trig-
ger .
Parameters:
<Source>
INTernal | NEXT
INTernal
Switch over to any segment is triggered manually by means of
the command
BB:ARB:WSEG:NEXT:EXEC
.
NEXT
The trigger event for switching to the next segment is input on
the NEXT connector.
*RST:
INTernal
Example:
BB:ARB:WSEG:NEXT:SOUR INT
selects internal next segment source.
[:SOURce<hw>]:BB:ARBitrary:WSEGment:SEQuence:APPend
<State>,
<Segment>, <Count>, <Next>
Appends a new segment to the selected sequencing play list.
Setting parameters:
<State>
ON | OFF
activates/deactivates the appended segment
*RST:
ON
<Segment>
integer
indicates the number of the segment as in the multi segment
waveform file
Range:
0 to SegmentCount - 1
<Count>
integer
defines how many times this segment is repeated
Range:
1 to 65535
<Next>
NEXT | BLANk | ENDLess | SEG0 | SEG1 | ... | SEG31 |
0...maxSegment
determines the action after completing the current segment, like
for instance which segment is processed after the processing of
the current one is finished.