Remote Control Commands
R&S
®
SGT100A
339
User Manual 1176.8674.02 ─ 07
Example:
SLISt:LIST?
// Response: "NRP33SN-V-900007-USB Legacy","NRP-Z211-900001-USB Legacy"
// list of automatically detected sensors
SLISt:SCAN:STATe 1
// searches for sensors connected in the LAN or via the USBTMC protocol
SLISt:LIST?
// Response:
// "NRP33SN-V-900007-USB Legacy","NRP-Z211-900001-USB Legacy",
// "NRP33SN-V-900005-USBTMC","NRP33SN-V-900011-LAN"
// the list contains more entries
SLISt:ELEMent3:MAPPing SENS1
// maps the third sensor from the list to the first sensor channel
Usage:
Query only
Manual operation:
See
:SLISt:SCAN[:STATe]
<State>
Starts the search for R&S
NRP power sensors, connected in the LAN or via the
USBTMC protocol.
Parameters:
<State>
0 | 1 | OFF | ON
*RST:
0
Example:
See
Manual operation:
See
:SLISt:ELEMent<ch>:MAPPing
<Mapping>
to one of the four sensor channels.
Parameters:
<Mapping>
SENS1 | SENSor1 | SENS2 | SENSor2 | SENS3 | SENSor3 |
SENS4 | SENSor4 | UNMapped
Sensor channel.
*RST:
UNMapped
Example:
See
Manual operation:
See
SENSe, READ, INITiate and SLISt Subsystems