Mixed signal option (MSO, R&S
RTO6-B1)
R&S
®
RTO6
999
User Manual 1801.6687.02 ─ 05
Figure 14-1: Edge trigger settings for trigger source = logical combination of digital channels (Logic)
Slope
Defines the edge - the state transition - of the signal.
"Positive"
Means a 0 to 1 transition of the state.
"Negative"
Means a 1 to 0 transition of the state.
"Either"
Triggers on any activity on the selected trigger source.
Remote command:
TRIGger<m>:PARallel:EDGE:SLOPe
Logical expression
Defines a logical combination of several digital channels as trigger condition if "Logic"
is set for "Source".
If the "Slope" is positive, the trigger occurs when the logical expression becomes true.
If the "Slope" is negative, the trigger occurs when the logical expression becomes
false.
Remote command:
TRIGger<m>:PARallel:EDGE:EXPRession[:DEFine]
14.3.1.3
Width
The width trigger detects positive and/or negative pulses of a pulse width (duration)
inside or outside of a defined time limit. It can trigger on a single digital channel or a
logical combination of digital channels.
The instrument triggers at the end of the detected pulse.
Trigger