User Manual 1801.6687.02 ─ 05
You can refine the trigger condition:
●
●
Remote command:
Handshake
Sets the trigger to one out of four different handshake types:
●
"ACK"
●
"NAK"
●
"STALL"
●
"NYET"
If no handshake condition is set, the trigger instant is after the PID.
If the PID error check is selected:
●
If an error is found in the PID's complementary form, the trigger is set immediately
after the 8
th
bit of the PID.
●
If no PID error is found, no trigger is set.
See
Remote command:
Special PID
Sets the trigger to one out of four different "Special PID" types:
●
"PREamble"
●
"ERR"
●
"SPLIT"
●
"PING"
If no additional conditions are set, the trigger instant is after the PID.
If the PID error check is selected:
●
if an error is found in the PID's complementary form, the trigger is set immediately
after the 8
th
bit of the PID
USB (option R&S