Spectrum analysis
R&S
®
RTO6
381
User Manual 1801.6687.02 ─ 05
Span/RBW Ratio
Defines the coupling ratio for Span/RBW. This setting is only available if
MATH<m>:FFT:BANDwidth[:RESolution]:AUTO
is ON.
Remote command:
CALCulate:MATH<m>:FFT:BANDwidth[:RESolution]:RATio
Resolution BW
Defines the resolution bandwidth. Note that the resolution bandwidth is correlated with
the span, record length and acquisition time. If a constant record length is to be used,
the RBW may be adapted if the required number of samples cannot be acquired. If
span and RBW values are coupled, changing the span will also change the RBW.
For details see
Chapter 9.1.1, "Fundamentals of FFT analysis"
Remote command:
CALCulate:MATH<m>:FFT:BANDwidth[:RESolution][:VALue]
CALCulate:MATH<m>:FFT:BANDwidth[:RESolution]:ADJusted?
Window type
Windowing helps minimize the discontinuities at the end of the measured signal inter-
val and thus reduces the effect of spectral leakage, increasing the frequency resolu-
tion.
Various different window functions are provided in the R&S
RTO6 to suit different input
signals. Each of the window functions has specific characteristics, including some
advantages and some trade-offs. Consider these characteristics carefully, to find the
optimum solution for the measurement task.
Window type
Frequency
resolution
Magnitude
resolution
Measurement recommendation
Rectangular
Best
Worst
Separation of two tones with almost equal amplitudes
and a small frequency distance
Hamming
Hann
Good
Poor
Frequency response measurements, sine waves, peri-
odic signals and narrow-band noise
Blackman Harris
(default)
Worst
Best
Mainly for signals with single frequencies to detect har-
monics
Accurate single-tone measurements
Gaussian
Good
Good
Weak signals and short duration
Flattop2
Poor
Best
Accurate single-tone measurements
Kaiser Bessel
Poor
Good
Separation of two tones with differing amplitudes and a
small frequency distance
Remote command:
CALCulate:MATH<m>:FFT:WINDow:TYPE
Use color table
If enabled, the spectrum waveform (and a spectrogram, if available) is displayed
according to the assigned color table. For information on the available color tables, see
FFT analysis