Remote control commands
R&S
®
RTO6
2516
User Manual 1801.6687.02 ─ 05
CDR:HARDware:SERStandard
<SerialStandard>
Sets the serial standard. Set
CUSTOM
to adjust the bit rate and the bandwidth manually.
Parameters:
<SerialStandard>
*RST:
CUSTOM
Usage:
Asynchronous command
CDR:HARDware:BREStimate
Estimates the bite rate once, for the current acquisition.
Usage:
Event
Asynchronous command
CDR:HARDware:BITRate
<Bitrate>
Parameters:
<Bitrate>
Range:
200E+3 to 2.5E+9 for 10 GSa/s; range depends
on sample rate
Increment: 10
*RST:
1E+9
Default unit: bps
Usage:
Asynchronous command
CDR:HARDware:ESLope
<Edge>
Selects the edges of the data stream that are used for the clock recovery.
●
"Either": Both positive and negative edges are used
●
"Positive / Negative": Only one edge direction is used. Use one of these settings if
the other edge might deliver unreliable results.
Parameters:
<Edge>
POSitive | NEGative | EITHer
*RST:
EITHer
Usage:
Asynchronous command
CDR:HARDware:PLL:ORDer
<PLLOrder>
Sets the order of the PLL: first or second order. PLL of higher order can compensate
for more complex jitter behavior.
Parameters:
<PLLOrder>
FIRSt | SECond
*RST:
FIRSt
Usage:
Asynchronous command
Jitter analysis and clock data recovery