![R&S RTO6 User Manual Download Page 2467](http://html2.mh-extra.com/html/rands/rto6/rto6_user-manual_30646462467.webp)
Remote control commands
R&S
®
RTO6
2467
User Manual 1801.6687.02 ─ 05
Usage:
Event
Asynchronous command
TDRT:TYPE
<Type>
Selects the analysis type: TDR (time domain reflectometry), TDT (time domain trans-
mission), or TDR/TDT (both TDR and TDT).
Parameters:
<Type>
TDR | TDRTdt | TDT
*RST:
TDR
Usage:
Asynchronous command
TDRT:PULSe:OUT
<Channel>
Sets the channel to which the "Out" connector of the pulse source is connected via cal-
ibration standard or DUT.
Parameters:
<Channel>
C1W1 | C2W1 | C3W1 | C4W1
*RST:
C2W1
Usage:
Asynchronous command
TDRT:PULSe:REFerence
<Channel>
Sets the channel to which the "Ref" connector of the pulse source is connected.
Parameters:
<Channel>
C1W1 | C2W1 | C3W1 | C4W1
*RST:
C1W1
Usage:
Asynchronous command
TDRT:SLENgth
<ShortLength>
Sets the electrical length of a user-defined short.
The reset value is the electrical length of the short hat is delivered with the pulse
source R&S
RTO6-B7.
Parameters:
<ShortLength>
Range:
0 to 2E-9
Increment: 1E-12
*RST:
26.5E-12
Default unit: s
Usage:
Asynchronous command
Pulse Source and TDR/TDT Analysis (options R&S
RTO6-B7/K130)