Remote control commands
R&S
®
RTO6
1843
User Manual 1801.6687.02 ─ 05
For complete definition, set also the operator with
Parameters:
<WordCount>
Range:
1 to 8
Increment: 1
*RST:
1
TRIGger<m>:LIN:IDOR<n>:ENABle
<UseIdentifier>
Includes the indicated IDOR address in the "identifier OR" trigger condition.
Suffix:
<n>
.
1..4
Index of the identifier in an "identifier OR" condition
Parameters:
<UseIdentifier>
ON | OFF
*RST:
OFF
TRIGger<m>:LIN:IDOR<n>[:VALue]
<IdPattern>
Defines the pattern of the indicated IDOR identifier in the "identifier OR" trigger condi-
tion.
Suffix:
<n>
.
1..4
Index of the identifier in an "identifier OR" condition
Parameters:
<IdPattern>
Numeric or string pattern, see
on page 1286. The parameter accepts the bit value
X (don't care).
TRIGger<m>:LIN:SYERror
<SyncError>
Triggers if a synchronization error occurs.
The trigger type has to be set before:
to
ERRC
.
Parameters:
<SyncError>
ON | OFF
*RST:
ON
TRIGger<m>:LIN:IPERror
<IdParityError>
Triggers if an error occurs in the identifier parity bits. These are the bits 6 and 7 of the
identifier.
The trigger type has to be set before:
to
ERRC
.
Protocols