Remote control commands
R&S
®
RTO6
1822
User Manual 1801.6687.02 ─ 05
SEARch:TRIGger:CAN:DLC
<SearchName>,<WordCount>
SEARch:TRIGger:CAN:DLC?
<SearchName>
Sets the Data Length Code, the number of data bytes to be found. For complete defini-
tion, set also the operator with
SEARch:TRIGger:CAN:DLCCondition
.
Parameters:
<WordCount>
Range:
1 to 8
Increment: 1
*RST:
1
Parameters for setting and query:
<SearchName>
SEARch:RESult:CAN:FRAMe<m>:NDBYtes?
<SearchName>
Returns the number of data bytes defined by DLC. DLC and NDB are different in CAN
FD for DLCs
>
8.
See also:
"Data setup: DLC, NDB, Transfer, Condition, Data min, Data max"
Suffix:
<m>
.
*
Query parameters:
<SearchName>
Return values:
<NDBytes>
Range:
1 to 64
Increment: 1
*RST:
1
Usage:
Query only
SEARch:TRIGger:CAN:FDATa:DPOPerator
<SearchName>,<DataPosOperator>
SEARch:TRIGger:CAN:FDATa:DPOPerator?
<SearchName>
Sets the operator for the data position if DLC
≥
9. You can define an exact position, or
a position range.
The setting is available in CAN FD option.
Parameters:
<DataPosOperator> ANY | OFF | EQUal | GETHan | INRange | RANGe
ANY = OFF
The data position is not relevant for the search.
EQUal | GETHan
Equal, Greater or equal than. These conditions require one data
position to be set with
Protocols