Remote control commands
R&S
®
RTO6
1495
User Manual 1801.6687.02 ─ 05
MEASurement<m>:AMPTime:DELay<n>:ECOunt
<EdgeIndex>
Sets the number of the edge that is relevant for delay measurement for each source.
Suffix:
<m>
.
1..10
See
"Selection of the measurement group: MEASurement<m>"
<n>
1..2
Selects the source number.
Parameters:
<EdgeIndex>
Edge number
Range:
1 to 100000
Increment: 1
*RST:
1
Usage:
Asynchronous command
MEASurement<m>:AMPTime:DELay<n>:LSELect
<DlyLevSel>
Selects the reference level on which the time is measured for each source.
Suffix:
<m>
.
1..10
See
"Selection of the measurement group: MEASurement<m>"
<n>
1..2
Selects the source number.
Parameters:
<DlyLevSel>
UPPer | MIDDle | LOWer
*RST:
MIDDle
Usage:
Asynchronous command
MEASurement<m>:AMPTime:DELay<n>:SLOPe
<Slope>
Sets the edge of each source, between which the delay is measured.
Suffix:
<m>
.
1..10
See
"Selection of the measurement group: MEASurement<m>"
<n>
1..2
Selects the source number.
Parameters:
<Slope>
POSitive | NEGative | EITHer
*RST:
POSitive