Waveform parameter
Many commands requires one of the waveforms to be specified as source. The follow-
ing table lists all waveforms. For each command using a waveform parameter, the
available waveforms are specified in the command description.
Waveform
Description
C1W1 | C1W2 | C1W3
Channel 1 waveforms
C2W1 | C2W2 | C2W3
Channel 2 waveforms
C3W1 | C3W2 | C3W3
Channel 3 waveforms
C4W1 | C4W2 | C4W3
Channel 4 waveforms
M1 | M2 | M3 | M4 | M5 | M6 | M7 | M8
Math waveforms
R1 | R2 | R3 | R4
Reference waveforms
XY1 | XY2 | XY3 | XY4
XY-waveforms
MRESult1 | MRESult2 | MRESult3 | MRESult4 |
MRESult5 | MRESult6 | MRESult7 | MRESult8
Measurement results
SBUS1 | SBUS2 | SBUS3 | SBUS4
Serial buses
D0 | D1 | D2 | D3 | D4 | D5 | D6 | D7 | D8 | D9 | D10
| D11 | D12 | D13 | D14 | D15
Digital channels (option R&S
RTO6-B1)
MSOB1 | MSOB2 | MSOB3 | MSOB4
Digital buses (option R&S
RTO6-B1
TRK1 | TRK2 | TRK3 | TRK4 | TRK5 | TRK6 | TRK7
| TRK8
Track waveforms
CDRSW1 = CDRSw1, CDRSW2 = CDRSw2
CDRHW = CDRHw
Generated clock signals
SG1 | SG2 | SG3 | SG4
Spectrograms (option R&S
RTO6-K37)
SG5 | SG6 | SG7 | SG8
Advanced jitter analysis (option R&S
RTO6-K133)
SG1TL1, SG1TL2, SG2TL1, SG2TL2, SG3TL1,
SG3TL2, SG4TL1, SG4TL2
Spectrograms (option R&S
RTO6-K37)
SG5TL1, SG5TL2, SG6TL1, SG6TL2, SG7TL1,
SG7TL2, SG8TL1, SG8TL2
Advanced jitter analysis (option R&S
RTO6-K133)
EYE1 | EYE2 | EYE3 | EYE4
Available for eye diagram analysis with option
R&S
RTO6-K91
Z1V1 | Z1V2 | Z1V3 | Z1V4 | Z1I1 | Z1I2 | Z1I3 |
Z1I4 | Z2V1 | Z2V2 | Z2V3 | Z2V4 | Z2I1 | Z2I2 |
Z2I3 | Z2I4
Z1V1 | Z1V2 | Z1I1 | Z1I2 | Z2V1 | Z2V2 | Z2I1 |
Z2I2
Input channels of multi-channel probe R&S
RT-
ZVC04
Input channels of multi-channel probe R&S
RT-
ZVC02
DIFF1 | DIFF2 | COMMON1 | COMMON2
Resulting waveforms of differential deembedding
TDRZ | TDRH | TDRR
Resulting waveforms of TDR/TDT analysis (option
R&S
RTO6-K130)
SEYE1 | SEYE2
Available for synthetic eye diagram analysis with
option R&S
RTO6-