Power analysis (option R&S
RTO6-K31)
R&S
®
RTO6
1190
User Manual 1801.6687.02 ─ 05
Execute
Starts the "Output Ripple" measurement.
Remote command:
19.6.2
Transient response
The "Transient Response" analysis measures the response of a system to a change
from equilibrium. This response is described by different properties like the rise time,
the overshoot, the settling time, the peak time and the delay time.
Required probes:
●
One or two voltage probes
●
Current probe
19.6.2.1
Transient response results
The results of " Power Quality" measurements are provided in two ways:
●
The diagram shows the graphical presentation of:
–
the voltage waveforms
–
the current waveform
●
The result box displays the numeric measurement results.
To measure and display the transient response, the instrument uses the following mea-
surements and waveforms:
●
MG 8 to measure the rise time, the overshoot and delay to trigger
●
"Cu 1" Cursor 3 to measure the peak time
●
"Cu 2" Cursor 2 to measure the delay to trigger
The used resources are listed in the "Details" tab. See also:
The results describing the transient response of the system are shown in
.
Output