Remote Control Commands
R&S
®
NRX
185
User Manual 1178.5566.02 ─ 05
Parameters:
<value>
Range:
0.005 to 2e18
*RST:
10.0
Default unit: -
Manual operation:
See
CALCulate<Measurement>:TRACe:Y[:SCALe]:SPAN:WATT
<value>
Effective for trace measurements.
Specifies the value range for the power axis.
Suffix:
<Measurement>
.
1 to 4
Measurement channel
Parameters:
<value>
Range:
1e-12 to 2e9
*RST:
1e-3
Default unit: W
Manual operation:
See
CALCulate<Measurement>:TRACe:Y[:SCALe]:TOP:DB
<value>
Effective for trace measurements.
Specifies the reference value for the power axis.
Suffix:
<Measurement>
.
1 to 4
Measurement channel
Parameters:
<value>
Range:
-200.0 to 200.0
*RST:
25.0
Default unit: dB
Manual operation:
See
CALCulate<Measurement>:TRACe:Y[:SCALe]:TOP:DBM
<value>
Effective for trace measurements.
Specifies the reference value for the power axis.
Suffix:
<Measurement>
.
1 to 4
Measurement channel
Measurement Settings and Results