M3SR Series 4100
Control Unit Maintenance
3.102
Operating Manual 6175.4760.02 – 01
Start the initiated built-in test of the control unit.
Several tests are performed during initiated built-in
test (see sect. 6.2.5 Control Unit Built-In Test). During
IBIT also the CU LEDs flash for a short time. To make
sure that the four LEDs are working properly, observe
the LEDs during IBIT. If during IBIT an error occurs, the
IBIT status displayed in the central area of this menu
changes to 'ERROR'. To get more information about
the detected error press softkey 'Error...' to navigate to
menu Control Unit Error List (see ”Control Unit Error
List (4011)” on p. 3.103).
Navigate to the menu CU MTC 2/4 (see sect. 3.5.2 Control
Unit MTC 2/4 (4002)).
Softkey
Description
Possible Values
Summary of Contents for M3SR 4100 Series
Page 15: ...M3SR Series 4100 Documentation Overview xiv Operating Manual 6175 4760 02 01...
Page 48: ...M3SR Series 4100 Index 34 Operating Manual 6175 4760 02 01 ZF4401 mod 02 2 10...
Page 70: ...M3SR Series 4100 Radio Control 1 22 Operating Manual 6175 4760 02 01...
Page 116: ...M3SR Series 4100 Example Configuration 2 46 Operating Manual 6175 4760 02 01...
Page 336: ...M3SR Series 4100 Priority Channel 3 220 Operating Manual 6175 4760 02 01...
Page 696: ...M3SR Series 4100 Remote Control 8 4 Operating Manual 6175 4760 02 01...
Page 697: ...Operating Manual 6175 4760 02 01 9 1 M3SR Series 4100 Drawings 9 Drawings...
Page 706: ...M3SR Series 4100 Drawings 9 10 Operating Manual 6175 4760 02 01...