Remote control commands
R&S
®
LCX Series
221
User Manual 1179.2260.02 ─ 02
SYSTem:RWLock
Locks all front panel controls, i.e. manual operation.
To unlock the front panel control, use command
Example:
See
Example "General instrument settings"
Usage:
Event
SYSTem:SETTing:DEFault:SAVE
[<File path>]
Saves the current instrument settings in a file with defined filename.
To recall an instrument configuration, use command
Setting parameters:
<File path>
Example:
See
Example "General instrument settings"
Usage:
Setting only
SYSTem:TIME
<Hour>, <Minute>, <Second>
Sets or queries the time for the instrument-internal clock.
The R&S
LCX indicates the time in the status bar.
Parameters:
<Hour>
Range:
0 to 23
<Minute>
Range:
0 to 59
<Second>
Range:
0 to 59
Example:
See
Example "General instrument settings"
Manual operation:
See
SYSTem:UPTime?
Queries the up time of the operating system.
Example:
See
Example "General instrument settings"
Usage:
Query only
SYSTem subsystem