Remote Commands
R&S
®
FSW
854
User Manual 1173.9411.02 ─ 43
PASSED
Limit check has passed.
FAIL
Limit check has failed.
Example:
INIT:IMM;*WAI;
CALC:LIM:ACP:ACH:RES?
PASSED,PASSED
Usage:
Query only
Manual operation:
See
See
CALCulate<n>:LIMit<li>:ACPower:ACHannel[:RELative]:STATe
This command turns the relative limit check for the adjacent channels on and off.
You have to activate the general ACLR limit check before using this command with
CALCulate<n>:LIMit<li>:ACPower[:STATe]
.
Suffix:
<n>
.
irrelevant
<li>
irrelevant
Parameters:
<State>
ON | OFF | 1 | 0
Relative limit check for lower adjacent channel
*RST:
0
<State>
Manual operation:
See
See
CALCulate<n>:LIMit<li>:ACPower:ALTernate<ch>:ABSolute
<LowerLimit>[,
<UpperLimit>]
This command defines the absolute limit of the alternate channels.
If you have defined an absolute limit as well as a relative limit, the R&S
FSW uses the
lower value for the limit check.
Suffix:
<n>
.
irrelevant
<li>
irrelevant
<ch>
1..n
Alternate channel number
Configuring and Performing Measurements