
Remote Commands
R&S
®
FSW
852
User Manual 1173.9411.02 ─ 43
CALCulate<n>:LIMit<li>:ACPower:ALTernate<ch>:RESult?
................................................856
CALCulate<n>:LIMit<li>:ACPower:ALTernate<ch>[:RELative]:STATe
...................................857
CALCulate<n>:LIMit<li>:ACPower[:STATe]
....................................................................... 857
CALCulate<n>:LIMit<li>:ACPower:ACHannel:ABSolute
<LowerLimit>[,
<UpperLimit>]
This command defines the absolute limit of the adjacent channels.
If you have defined an absolute limit as well as a relative limit, the R&S
FSW uses the
lower value for the limit check.
Suffix:
<n>
.
irrelevant
<li>
irrelevant
Parameters:
<LowerLimit>
The limit of the lower adjacent channel.
Range:
-200 dBm to 200 dBm
*RST:
-200 dBm
Default unit: dBm
<UpperLimit>
The limit of the upper adjacent channel.
Range:
-200 dBm to 200 dBm
*RST:
-200 dBm
Default unit: dBm
Manual operation:
See
See
CALCulate<n>:LIMit<li>:ACPower:ACHannel:ABSolute:STATe
This command turns the absolute limit check for the adjacent channels on and off.
You have to activate the general ACLR limit check before using this command with
CALCulate<n>:LIMit<li>:ACPower[:STATe]
.
Suffix:
<n>
.
irrelevant
<li>
irrelevant
Parameters:
<State>
ON | OFF | 1 | 0
Absolute limit check for lower adjacent channel
*RST:
0
<State>
Manual operation:
See
See
Configuring and Performing Measurements