Measurements and Results
R&S
®
FSW
348
User Manual 1173.9411.02 ─ 43
Remote command:
[SENSe:]BANDwidth[:RESolution]
[SENSe:]BANDwidth[:RESolution]:AUTO
Automatic Peak Search
If activated, a peak search is performed automatically for all active markers after each
sweep.
If Auto peak search
and
limit lines are active, the active markers are set to the peak
delta
values between the measured signal and the limit lines.
Note:
Auto Max Peak Search / Auto Min Peak Search
are not available for EMI measurements.
Remote command:
CALCulate<n>:MARKer<m>:FUNCtion:FMEasurement:PEAKsearch:AUTO
Dwell Time
Sets the dwell time for the EMI marker measurement.
For more information see
Chapter 7.13.3.2, "Detectors and Dwell Time"
Remote command:
CALCulate<n>:MARKer<m>:FUNCtion:FMEasurement:DWELl
Frequency Axis Scaling
Switches between linear and logarithmic scaling for the frequency axis.
By default, the frequency axis has linear scaling. Logarithmic scaling of the frequency
axis, however, is common for measurements over large frequency ranges as it enhan-
ces the resolution of the lower frequencies. On the other hand, high frequencies get
more crowded and become harder to distinguish.
For more information see
Chapter 8.3.1.3, "Coping with Large Frequency Ranges -
Remote command:
DISPlay[:WINDow<n>][:SUBWindow<w>]:TRACe<t>:X:SPACing
Res BW CISPR
Defines the measurement bandwidth for commercial EMC standards according to
CISPR.
For more information see
Chapter 7.13.3.1, "Resolution Bandwidth and Filter Types"
Remote command:
Filter type:
[SENSe:]BANDwidth[:RESolution]:TYPE
Filter bandwidth:
[SENSe:]BANDwidth[:RESolution]
Res BW MIL
Defines the measurement bandwidth for military EMC standards.
Electromagnetic Interference (EMI) Measurement