Remote Commands for Analog Demodulation Measurements
R&S
®
FSW-K7
322
User Manual 1173.9240.02 ─ 23
CALCulate<n>:MARKer<m>:Y?
This command queries the position of a marker on the y-axis.
If necessary, the command activates the marker first.
To get a valid result, you have to perform a complete measurement with synchroniza-
tion to the end of the measurement before reading out the result. This is only possible
for single sweep mode.
See also
If the analog demodulator (option Analog Demodulation, R&S
FSW–K7) is activated,
the query result is output in the following units in the specified window:
Result display
Output unit
AM
%
FM
Hz
PM
RF
dB (Range Log or Range Linear %)
% (Range Linear dB)
Suffix:
<n>
.
<m>
Return values:
<Result>
Result at the marker position.
Example:
INIT:CONT OFF
Switches to single measurement mode.
CALC:MARK2 ON
Switches marker 2.
INIT;*WAI
Starts a measurement and waits for the end.
CALC:MARK2:Y?
Outputs the measured value of marker 2.
Usage:
Query only
Manual operation:
See
See
CALCulate<n>:DELTamarker<m>:AOFF
This command turns off
all
delta markers.
Suffix:
<n>
.
<m>
irrelevant
Analyzing Results