Remote Commands for Analog Demodulation Measurements
R&S
®
FSW-K7
315
User Manual 1173.9240.02 ─ 23
Suffix:
<n>
.
<t>
<m>
irrelevant
Parameters:
<SINAD>
The signal-to-noise-and-distortion ratio in dB.
Usage:
Query only
CALCulate<n>:MARKer<m>:FUNCtion:ADEMod:THD:RESult<t>?
This command queries the result of the total harmonic distortion (THD) measurement
in the specified window.
Note that this value is only calculated if an AF Spectrum window is displayed.
Suffix:
<n>
.
<t>
<m>
irrelevant
Parameters:
<THD>
Total harmonic distortion of the demodulated signal in dB.
Usage:
Query only
[SENSe:]ADEMod<n>:FM:OFFSet?
<ResultType>
This command calculates the FM carrier offset from the currently available measure-
ment data set.
If averaging has been activated before acquiring the data set (using
]ADEMod<n>:FM[:TDOMain]:RESult?
on page 308, the averaged FM offset over
several measurements can also be obtained by setting <ResultType> = AVERage.
The offset thus determined differs from the one calculated by the
MARKer<m>:FUNCtion:ADEMod:FERRor[:RESult<t>]?
since, for determination of the frequency deviation, the modulation is removed by
means of low pass filtering, producing results that are different from those obtained by
averaging.
Suffix:
<n>
.
irrelevant
Retrieving Results