Remote Commands for Analog Demodulation Measurements
R&S
®
FSW-K7
313
User Manual 1173.9240.02 ─ 23
Query parameters:
<MeasType>
PPEak | MPEak | MIDDle | RMS
PPEak
Postive peak (+PK)
MPEak | NPEak
Negative peak (-PK)
MIDDle
Average of positive and negative peaks ±PK/2
RMS
Root mean square value
Example:
CALC:FEED 'XTIM:PM:TDOM'
Switches on the PM time domain result display.
DISP:TRAC ON
Switches on the trace.
CALC:MARK:FUNC:ADEM:PM? PPE
Queries the peak value of the demodulated PM trace.
Usage:
Query only
Manual operation:
See
CALCulate<n>:MARKer<m>:FUNCtion:ADEMod:AM[:RESult<t>]:RELative?
<MeasType>
CALCulate<n>:MARKer<m>:FUNCtion:ADEMod:FM[:RESult<t>]:RELative?
<MeasType>
CALCulate<n>:MARKer<m>:FUNCtion:ADEMod:PM[:RESult<t>]:RELative?
<MeasType>
This command queries the current
relative
value of the demodulated signal for the
specified trace (as displayed in the Result Summary in manual operation).
Note that all windows with the same evaluation method have the same traces.
The unit of the results depends on the
setting.
Suffix:
<t>
.
<n>, <m>
irrelevant
Query parameters:
<MeasType>
PPEak
Postive peak (+PK)
MPEak | NPEak
Negative peak (-PK)
MIDDle
Average of positive and negative peaks ±PK/2
RMS
Root mean square value
Retrieving Results