![R&S FSW-K7 User Manual Download Page 303](http://html1.mh-extra.com/html/rands/fsw-k7/fsw-k7_user-manual_3082493303.webp)
Remote Commands for Analog Demodulation Measurements
R&S
®
FSW-K7
303
User Manual 1173.9240.02 ─ 23
Example:
LAY:CAT?
Result:
'2',2,'1',1
Two windows are displayed, named '2' (at the top or left), and '1'
(at the bottom or right).
Usage:
Query only
LAYout:IDENtify[:WINDow]?
<WindowName>
This command queries the
index
of a particular display window in the active measure-
ment channel.
Note
: to query the
name
of a particular window, use the
query.
Query parameters:
<WindowName>
String containing the name of a window.
Return values:
<WindowIndex>
Index number of the window.
Example:
LAY:WIND:IDEN? '2'
Queries the index of the result display named '2'.
Response:
2
Usage:
Query only
LAYout:REMove[:WINDow]
<WindowName>
This command removes a window from the display in the active measurement channel.
Parameters:
<WindowName>
String containing the name of the window.
In the default state, the name of the window is its index.
Example:
LAY:REM '2'
Removes the result display in the window named '2'.
Usage:
Event
LAYout:REPLace[:WINDow]
<WindowName>,<WindowType>
This command replaces the window type (for example from "Diagram" to "Result Sum-
mary") of an already existing window in the active measurement channel while keeping
its position, index and window name.
To add a new window, use the
Configuring the Result Display